background image

 

 

 

213-251 
252-255 

Random strobe from slow to fast 
Shutter open → (controlled by dimming channel) 

Dimmer   

000-255 

   

Gobo wheel    000 - 004 

005 - 009 
010 - 014 
015 - 019 
020 - 024 
025 - 029 
030 - 034 
035 - 039 
040 - 044 
045 - 049 
050 - 054 
055 - 059 
060 - 064 
065 - 069 
070 - 074 
075 - 079 
080 - 084 
085 - 089 
090 - 094 
095 - 099 
100 - 104 
105 - 109 
110 - 114 
115 - 119 
120 - 124 
125 - 129 
130 - 134 
135 - 139 
140 - 200 
201 - 255 

Solid figure 1 
Solid picture 2 
Solid figure 3 
Solid figure 4 
Solid Figure 5 
Solid figure 6 
Solid figure 7 
Solid figure 8 
Solid figure 9 
Solid figure 10 
Solid figure 11 
Solid figure 12 
Solid figure 13 
Solid figure 14 
Fixed image 1 (from slow to fast) 
Fixed image 2 (from slow to fast) 
Fixed image 3

Slow to fast) 

Fixed image 4 (from slow to fast) 
Fixed image 5 (from slow to fast) 
Fixed image 6 (from slow to fast) 
Fixed image 7 (from slow to fast) 
Fixed image 8 (from slow to fast) 
Fixed image 9 (from slow to fast) 
Fixed image10 (from slow to fast) 
image11 (from slow to fast) 
Fixed image 12 (from slow to fast) 
Fixed image 13 (from slow to fast) 
Fixed image 14 (from slow to fast) 
Reverse flow (from fast to slow) 
Positive flow (from slow to fast) 

Prism 1

 

000-127 
128-255 

Prism 1 pops up 
Prism 1 cut in 

Prism   

rotation

 

000-127 
128-190 
191-192 
193-255 

Prism angle adjustment 
Reverse rotation (from fast to slow) 
stop 
Forward rotation (from slow to fast

 

Prism 2

 

000-127 
128-255 

Prism 2 pops up 
Prism 2 cut in 

Prism 2 

rotation

 

000-127 
128-190 
191-192 

Prism angle adjustment 
Reverse rotation (from fast to slow) 
stop 

Summary of Contents for VELA 250B

Page 1: ...VELA 250B User Manual ...

Page 2: ... 1 2 Maintainance 1 1 3 Product precautions 1 1 4 Product description 1 1 5 DMX connect 2 1 6 Fixture installing 2 2 LCD display 4 2 1 Menu key 4 2 2 Menu 5 2 2 1 Manual set 5 2 2 2 Set 6 2 2 3 System 7 3 Function DMX 8 3 1DMX chart 8 4 Common error 11 ...

Page 3: ...s necessary to clean the fan fan net and lens frequently Do not wipe the lamp housing with organic solvents such as alcohol to avoid damage Product precautions This lamp is for professional use only Before operation make sure that the power supply voltage matches the power supply voltage required by the equipment Do not place the product in a place that is easy to loose or shake Stop using the lam...

Page 4: ...ll a terminal plug on the output 3 pin jack of the last connected lamp of each connection Weld a 4 1W 120Ω resistor between the 2 and 3 pins of the 3 pin XLR plug Important note the wires cannot touch each other or the metal shell Figure 1 Diagram of DMX signal line connection Calculation method of lamp start address code The starting address code of the current fixture is equal to the starting ad...

Page 5: ...all down on the support frame You need to use a safety rope to pass through the support frame and the luminaire lift Hand assist hanging to ensure safety and prevent the lamp from falling and sliding When the lamps are installed and debugged pedestrians are prohibited from passing underneath Regularly check whether the safety ropes are worn and the hook screws are loose Our company will not bear a...

Page 6: ... not the main interface press the left key one or more times to return to the main interface 2 In the main interface press Up or Down to select the Settings button 3 Press the OK button to enter the Settings interface 4 In the Settings interface press the Up or Down keys to select DMX Address 5 Press OK to enter the editing state 6 Press Up or Down to modify the DMX address code ...

Page 7: ...the up and down keys to change the channel value Press the OK key again to select the ten digits for editing Press the OK key again to select the ones digit to edit Press again to exit the editing state 0 255 14CH frost 0 255 16CH reset Press the OK button to see the confirmation dialog box press the OK button again to enter the reset interface and all motors are reset 16CH lamp control on Off 17C...

Page 8: ...nge Off On Exchange the channels of XY axis including fine adjustment XY Encoder On Use encoder optocoupler to judge out of step and automatically correct position Off Correct position without using encoder optocoupler DMX Keep Continue to run as it was Clear 0 Motor returns to position and stops running screen protector On Turn off the backlight after 30 seconds of idle Off Backlight always brigh...

Page 9: ...is detected 1 otherwise Prism 2 Hall 0 when magnetism is detected 1 otherwise X axis encoder disk status 2 digits each corresponding to a photoelectric switch in the encoding disk Y axis encoder disk status 2 digits each corresponding to a photoelectric switch in the encoding disk X axis encoder disc step value When walking in the positive direction the step value should increase and when walking ...

Page 10: ... wheel reset failed The color wheel Hall or the color wheel motor has a problem Gobo reset failed Gobo Hall or gobo motor has a problem Focus reset failed There is a problem with the focus hall or the focus motor Lamp control failed Failure to turn on or off the bulb there is a problem with the lighter or bulb 1 Function 3 1 DMX channel chart ch mode 16ch 20ch 1 Color wheel Color wheel 2 Cut light...

Page 11: ...ite light White light color 1 Color 1 Color 1 color 2 Color 2 Color 2 color 3 Color 3 Color 3 color 4 Color 4 Color 4 color 5 Color 5 color 6 Color 6 Color 6 color 7 Color 7 Color 7 color 8 Color 8 Color 8 color 9 Color 9 Color 9 color 10 Color 10 Color 10 color 11 Color 11 Color 11 color 12 Color 12 Color 12 color 13 Color 13 Color 13 white light Positive flow from fast to slow Reverse flow from ...

Page 12: ... from slow to fast Fixed image 3 Slow to fast Fixed image 4 from slow to fast Fixed image 5 from slow to fast Fixed image 6 from slow to fast Fixed image 7 from slow to fast Fixed image 8 from slow to fast Fixed image 9 from slow to fast Fixed image10 from slow to fast image11 from slow to fast Fixed image 12 from slow to fast Fixed image 13 from slow to fast Fixed image 14 from slow to fast Rever...

Page 13: ...olorful mirror cut in Atomized slice cut in 16 Bulb control 000 099 100 105 200 205 250 255 Invalid area Turn off the bulb Light up the bulb All motors reset 17 Keep 000 255 Speed from fast to slow 18 Color speed 19 Dimming Pri sm Atomizati on Speed 20 Gobo wheel speed 2 Common faults 1 For some common faults corresponding solutions are proposed Any problems that cannot be solved should be handled...

Page 14: ...n control line is correct the communication line is too long or has been interrupted Check whether the control equipment is invalid and check whether the serially connected signal amplifier is invalid Check whether the communication line is too long or other equipment interferes with each other Optimize wiring shorten the length of control signal lines and separate high voltage and low voltage lin...

Page 15: ...off or loose Check whether the electronic components of the lamp such as electronic transformers PCB boards motor control boards etc are loose short circuited and burned out 4 When working the X axis or Y axis of the lamp does not work properly Check one by one according to the previous step Check whether the transmission belt corresponding to the X and Y axis directions in the lamp is off or brok...

Reviews: