D6001DE-L Double Unit Series (Double Egress)
Power Operator
Double Door Vestibule Function Wiring Using Factory Pre-Wiring
• For Master/Follow or
Master-Coord/Follow
only (Sync Cable must
be used to connect
inverters .)
• Doors are normally
closed and latched .
• Activating outside
door switch will open
outside door . After
vestibule time delay
has elapsed, a signal
will be sent to inside
door which will open .
Activating inside door
switch will open inside
door . After vestibule
time delay has elapsed,
a signal will be sent to
outside door which will
open . Both doors will
close when hold open
time delay has elapsed .
• Activating optional
inside door switch
located within corridor
will open inside door
only . This door will re-
close after hold open
delay has elapsed .
• Activating optional
outside door switch
located within corridor
will open outside door
only . This door will re-
close after hold open
delay has elapsed .