Norton Assa Abloy D6001DE-L Series Installation Instructions Manual Download Page 16

Copyright © 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or

in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

80-9360-1037-020  Rev 3  11/20

16

D6001DE-L Double Unit Series (Double Egress)

 Power Operator

Attach Covers to finalize installation 

1 .  Align cut-outs in each cover to corresponding 

pinion shafts . (Figure 36) 

2 .  Slide covers onto units using end caps and 

union spacers as guides .  

 

NOTE: Verify all wiring and sheet metal 

guards are inside cover.

 

3 .  Snap covers securely to backplates . Pull on 

covers to verify they are secure . 

NOTE: If cover will not securely snap onto 

backplate, verify backplate is not warped or 

twisted. Additional support or shimming may 

be required. See Sections A & B under Prepare 

Frame and Door. 

WARNING: Make sure no wiring is loose or can be 

caught by cover when it is snapped into place.

Figure 36 

General Electrical Information 

•  Power inputs at power input connection and 

power output contacts must be made with 

copper wire only . 

• 

Maximum wire size:

12 AWG at power input connection 

14 AWG at all other terminals . 

•  Power input at terminals LINE and NEUTRAL 

must be 120VAC at 60 Hz (+10%, -15%) . 

Pinion Shaft Cut-out

Pinion Shaft Cut-out

•  Maximum current draw from auxiliary devices is 

1 .3 amps . 

•  All wiring and connections use standard wiring 

practice conforming with local wiring codes . 

•  Labeled fire or smoke barrier door assemblies 

require 120VAC 60Hz power input be supplied 

through normally closed alarm contacts of the 

alarm system / alarm panel.

Summary of Contents for Assa Abloy D6001DE-L Series

Page 1: ...0SUP Power Module Sub assembly 6001PM Closer Assembly 7500LAP Pour la version francaise voir www nortondoorcontrols com READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS This product can expose...

Page 2: ...rs can be installed and adjusted to conform with A D A regulations ANSI A117 1 These door controls permit door assemblies to conform to the requirements of this specification for buildings and facilit...

Page 3: ...hers required Closing When the hold open time has elapsed the door closer will close the door automatically The door will slow to low speed at latch before it reaches the fully closed position The doo...

Page 4: ...emplate information based upon use of 5 maximum width butt hinges Frame reveal is 2 1 4 to 4 3 4 for push arm and 1 8 to 3 for pull arm Before beginning the installation verify that the door frame is...

Page 5: ...ckplates can be used as reference NOTE If frame is not flat or is twisted additional steel back plates or shimming is required Failure to mount units properly can result in improper function of operat...

Page 6: ...igure 5 6 Using backplate as template mark conduit slot and Dim D mounting hole Figure 5 NOTE Dim D should be 1 up from frame rabbet if backplate is properly aligned 7 Drill hole for mounting screw at...

Page 7: ...between backplate and wall above header is HIGHLY recommended Material must comply with local codes Failure to properly secure top of backplate could result in operator being allowed to rock during op...

Page 8: ...ge edge of frame Slide each LAP over two 2 screws and tighten Figure 11 NOTE LAP for left door should have PUSH label and door closer valves should point toward chain LAP for right door should have PU...

Page 9: ...mbly so two 2 conduit holes are at bottom and text on wire input label is legible Figure 13 2 Secure assembly to backplate using four 4 8 32 x 5 16 Phillips head screws Figure 13 WARNING BUILDING POWE...

Page 10: ...ne way Install Operator Figure 16 Access Door Union Assembly View From Floor Spacer Spacer Union Assembly Mounting Screw typical Figure 17 Power Module Sub assembly 4 Pin Black Connector Power Module...

Page 11: ...ugh shoe and into sex bolts Figure 19 NOTE Orient shoe with long side of shoe toward hinge Figure 20 View from ceiling looking downward 1 Open left door 2 Slide forearm into main arm adjusting tube Fi...

Page 12: ...as shown Figure 28 4 Secure arm to pinion with 1 4 20 x 1 2 screw and countersunk patch washer Figure 27 5 Insert stud on arm into slider in track by pressing clip on backside of slider onto stud Fig...

Page 13: ...door open When finished slide access door closed and reinsert 6 Torx flat head screw to secure door Figure 32 Adjustments A Adjust mechanical closer features on each operator NOTE Make necessary mech...

Page 14: ...ight to increase decrease value NOTE Values will auto save 3 seconds after adjustments Figure 33 Figure 34 View From Floor Union Assembly Selector Mode Switches WARNING Door may begin to move immediat...

Page 15: ...e set Master door will open slightly before Follower door during opening cycle Upon closing if Master door reaches a set door opening position MasterStopOffset and Figure 35 Union Assembly Switches Fo...

Page 16: ...ackplate verify backplate is not warped or twisted Additional support or shimming may be required See Sections A B under Prepare Frame and Door WARNING Make sure no wiring is loose or can be caught by...

Page 17: ...ice connected to Aux 1 is sending constant signal Aux 2 Stuck Activation device connected to Aux 2 is sending constant signal Aux 3 Stuck Activation device connected to Aux 3 is sending constant signa...

Page 18: ...doors when door coordination is needed MastStopOffset 0 500 180 Adjustable point where Master Coord door will stop and wait for Follower door to fully close so Follower does not contact astragal attac...

Page 19: ...d Function with Switches For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed Fail Secure Electric Strike 24VDC Wiring For Master Follow...

Page 20: ...o NC For Master Follow or Master Coord Follow only Sync Cable must be used to connect inverters Doors are normally closed and latched Activating switch will energize exit device and door will automati...

Page 21: ...losed Activating switch will open door Door will remain in indefinite hold open until activating switch is activated a second time causing door to close Change Factory Pre Wiring to Illustration Below...

Page 22: ...be used to connect inverters Doors are normally closed and latched Fire Alarm activation will retract exit device latch bolt and door operator will open door Door will remain open until the Fire Alarm...

Page 23: ...hed Activating wireless switch or hand held wireless transmitter will open door Door will remain in indefinite hold open until wireless switch or hand held transmitter is activated a second time causi...

Page 24: ...e normally closed and latched Activating outside door switch will open outside door After vestibule time delay has elapsed a signal will be sent to inside door which will open Activating inside door s...

Page 25: ...teps 1 4 Hand Held Configuration depress push plate to activate transmitter 4 Attach transmitter to inside of electrical box and complete installation Removing Transmitter Code s Single Transmitter Co...

Page 26: ...sence Detector senses something in opening door will not close NOTE Presence Detector and or sensors CANNOT be used to active opening cycle of door To activate presence detector functionality On inver...

Page 27: ...roller screen If DT is set to Standard this is normal Door Toggle mode and will not work with Presence Sensor set to Stall door closing will stall until presence not sensed set to Return Open presence...

Page 28: ...reaches open position door drifts further open Decrease Hold Speed on controller see pages 14 and 18 until door stops drifting When door reaches open position door bounces Decrease Slow Speed on contr...

Page 29: ...opyright 2020 ASSA ABLOY Accessories and Door Controls Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls...

Reviews: