26
Troubleshooting
The manufacturer reserves the right to make improvements in design and/or changes in specifications at any time
without incurring any obligation to install them on units previously sold.
Problem
Solution
Motor will not start
SOLUTION: A, B, M, N, O
Low/Surging pressure or no water flow
SOLUTION: C, D, E, F, G, H
No chemical injection
SOLUTION: I, J, K, L
Cause
Solution
A-
Tripped GFCI cord
Reset GFCI cord
B-
Tripped motor relay
Reset motor
C-
Insufficient water supply
See water supply section of this manual
D-
Plugged pump inlet filter
See maintenance section of this manual
E-
Wrong nozzle
Make sure high-pressure nozzle is being used
F-
Plugged nozzle
Remove nozzle, check for blockage
G-
Worn nozzle
Replace nozzle
H-
Leak in pressure hose
Replace pressure hose
I-
Wrong nozzle
Make sure chemical nozzle is being used
J-
Back pressure from extra-long discharge hose
Try shorter hose
K-
Leak in chemical siphon hose
Replace hose
–
use hose clamps if necessary
L-
Chemical strainer not submerged
Make sure strainer is completely submerged
M-
Tripped circuit breaker
Make sure breaker is rated to 120V/15A for 1571101 &
120V/20A for 1571102 only
Make sure breaker is rated to 230V/30A for 1571103 &
1571104 and 230V/50A for 1571105 only
N-
Extension cord too long
Use extension cord with an appropriate rating for distance
O-
Debris in flow switch
Clean flow switch
Summary of Contents for 1571101