background image

North

Q

 

Power & Gas Reader 

Revision: 2.2 

11 

 

 

If calibration has failed you must inform the user that he didn't place the sensor head 

properly on the meter, he didn't plug the cable properly in the Power Reader or there is a very 
low consumption on the meter and the meter disk spins very slow. 
-  set  the  pulse  count  register  with  the  proper  value  (as  described  in 
COMMAND_CLASS_CONFIG) 
- show the user the real-time consumption using command class meter 
-  as  soon  as  the  user  finished  checking  the  real-time  consumption  send  the  Power  Reader  to 
sleep 

VII. Support 

 

Any support requests have to be submitted by email to [email protected] (Christian) or 

[email protected] (Florin). 

Summary of Contents for NQ-9021

Page 1: ...NorthQ Power Gas Reader Revision 2 2 1 NorthQ Power and Gas Reader NQ 9021 Technical Integration Z Wave Commands Document revision 2 2 Date January 30 2015...

Page 2: ...ranties or conditions whether expressed orally or implied in law including implied warranties and conditions of merchantability or fitness for a particular purpose NorthQ ApS specifically disclaims an...

Page 3: ...ng has different firmware than the Power Reader for gas metering Please make sure you have the appropriate firmware on your device before you start integrating installing it The proper way of distingu...

Page 4: ...is described in detail Make sure to read the Integrating with third party controllers part of the document after going through the command classes 1 COMMAND_CLASS_BASIC Using the command class basic t...

Page 5: ...entire firmware file including headers Initial crc value is 0xFFFF 5 COMMAND_CLASS_TIME_PARAMETERS Use this command class to set the Power Reader s real time clock The command class is implemented ac...

Page 6: ...ulse factor in imp Wh instead of imp kWh In this case the value must be converted to imp kWh before multiplying by 10 and writing this value in the register In order to convert imp Wh to imp kWh the v...

Page 7: ...e for the Power Reader within 3 seconds then this register should be set to the number of seconds that it will take the controlling node to send a response request to the wake up notification Register...

Page 8: ...irmware Manufacturer 150 Product 1 Product type 1 MANUFACTURER SPECIFIC for gas firmware Manufacturer 150 Product 1 Product type 16 10 COMMAND_CLASS_VERSION This command class is implemented according...

Page 9: ...e wake up node 255 most probably has historical data in his storage You can pull that from the Power Reader as the user might want to see his historical consumption through your UI use the basic comm...

Page 10: ...ess it is absolutely necessary as it will require the antenna to send more bytes than the regular command class By sending more bytes the battery lifetime is affected leave register 10 at 3 seconds If...

Page 11: ...consumption on the meter and the meter disk spins very slow set the pulse count register with the proper value as described in COMMAND_CLASS_CONFIG show the user the real time consumption using comma...

Reviews: