background image

North

Q

 

Power & Gas Reader 

Revision: 2.2 

 

 
 
 
 
 
 
 
 
 
 
 

Disclaimer: 

 
 

This document is provided for information purposes only. NorthQ ApS may change the contents 
hereof  without  notice.  This  document  is  not  warranted  to  be  error-free,  nor  subject  to  any 
other  warranties  or  conditions,  whether  expressed  orally  or  implied  in  law,  including  implied 
warranties  and  conditions  of  merchantability  or  fitness  for  a  particular  purpose.  NorthQ  ApS 
specifically disclaims any liability with respect to this document and no contractual obligations 
are  formed  either  directly  or  indirectly  by  this  document.  The  technologies,  functionality, 
services, and processes described herein are subject to change without notice. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for NQ-9021

Page 1: ...NorthQ Power Gas Reader Revision 2 2 1 NorthQ Power and Gas Reader NQ 9021 Technical Integration Z Wave Commands Document revision 2 2 Date January 30 2015...

Page 2: ...ranties or conditions whether expressed orally or implied in law including implied warranties and conditions of merchantability or fitness for a particular purpose NorthQ ApS specifically disclaims an...

Page 3: ...ng has different firmware than the Power Reader for gas metering Please make sure you have the appropriate firmware on your device before you start integrating installing it The proper way of distingu...

Page 4: ...is described in detail Make sure to read the Integrating with third party controllers part of the document after going through the command classes 1 COMMAND_CLASS_BASIC Using the command class basic t...

Page 5: ...entire firmware file including headers Initial crc value is 0xFFFF 5 COMMAND_CLASS_TIME_PARAMETERS Use this command class to set the Power Reader s real time clock The command class is implemented ac...

Page 6: ...ulse factor in imp Wh instead of imp kWh In this case the value must be converted to imp kWh before multiplying by 10 and writing this value in the register In order to convert imp Wh to imp kWh the v...

Page 7: ...e for the Power Reader within 3 seconds then this register should be set to the number of seconds that it will take the controlling node to send a response request to the wake up notification Register...

Page 8: ...irmware Manufacturer 150 Product 1 Product type 1 MANUFACTURER SPECIFIC for gas firmware Manufacturer 150 Product 1 Product type 16 10 COMMAND_CLASS_VERSION This command class is implemented according...

Page 9: ...e wake up node 255 most probably has historical data in his storage You can pull that from the Power Reader as the user might want to see his historical consumption through your UI use the basic comm...

Page 10: ...ess it is absolutely necessary as it will require the antenna to send more bytes than the regular command class By sending more bytes the battery lifetime is affected leave register 10 at 3 seconds If...

Page 11: ...consumption on the meter and the meter disk spins very slow set the pulse count register with the proper value as described in COMMAND_CLASS_CONFIG show the user the real time consumption using comma...