14
C. When you want you want to REFUEL… Electronic Control System is ON now.
1
Turn
OFF
the combustion chamber blower fan for the combustion
chamber
BEFORE
you open the combustion chamber loading
door. Toggle switch located on the upper right side of structure.
Flip combustion chamber blower
fan toggle switch
OFF
.
2
Follow step 3 on page 8 for refueling. Once wood is loaded, close
the combustion chamber loading door and turn
ON
the blower fan.
Toggle switch located on the upper right side of structure.
Flip combustion chamber blower
fan toggle switch
ON
.
D. When you want to shutdown the furnace for part replacement… Electronic Control is
ON now.
1
Turn
OFF
Electronic Control System. Turn the
“SYSTEM”
selector switch (D) from
ON
to
OFF,
on the Electronic Control
System. Caution! Many components of the furnace will be very hot
and may seriously injure you. Please allow the furnace to cool down
before attempting any maintenance.
Turn the “
SYSTEM
” selector
switch (D) to
OFF
.
Electronic Control
System
Summary of Contents for 30-30
Page 23: ...21 Notes...