background image

TECHNICAL DETAILS

 

 Do not leave this system unattended while any burner is lit or 
while heating.

 

 Monitor  the  system  when  hot  and  after  use  (temperatures 
above 100°F/38°C). Heated liquid and equipment can remain at 
scalding temperatures long after the boil has ended and burners 
have been shut off.

 

 Do not exceed 125 lbs. per burner assembly or 300 lbs. for the 
full system.

 

Do not use this system for heating oil or grease.

 

 Keep  children,  pets  and  unauthorized  persons  away  from  the 
Center of Gravity™ at all times.

 

 Always operate the system on a level, stable, noncombustible 
surface such as brick or concrete. Surfaces not suitable for use 
include wood, asphalt or plastic which may burn, blister or melt.

 

 This system is for outdoor use only. Do not use in a building, 
garage, tent or any other enclosed area. Do not use in or on a 
recreational vehicle or boat.

 

 Do  not  locate  this  system  under  any  overhead  construction. 
Keep  a  minimum  clearance  of  10  ft.  (3.05m)  from  the  sides, 
front and back of the burner to any construction. Keep the area 
clear of any combustible material. Do not use on or under any 
apartment or condo balcony or deck.

 

 Do not allow the flame to roll past the bottom of the brew kettle.

 

Do not install casters or wheels on the Center of Gravity™.

 

 Never lift or move a full kettle of water onto or off of the Center 
of Gravity™.

 

 Only use the propane tank valve as the gas shutoff. Do not use 
the regulator or needle valves.

 

 A 20-pound (9 kg) propane cylinder should be used with this 
burner. The LP-gas supply cylinder used must have a protective 
collar and must be constructed and marked in accordance with 
the  specifications  for  LP-gas  cylinders  of  the  U.S.  Department 
of  Transportation  (DOT),  cylinders,  spheres  and  tubes  for  the 
transportation of Dangerous Goods. Do not store a spare LP-gas 
cylinder indoors, or under or near the Center of Gravity™. Never 
fill the cylinder beyond 80% full. For proper vapor withdrawal, 
the 20 lb. (9 kg) cylinder should be used in the proper upright 
position. Cylinder must be turned off while not in use. Failure 
to follow these instructions and warnings could result in fire or 
explosion which could cause property damage, personal injury 
or death.

 

 Keep the gas supply hose away from heated surfaces at all times.

 

Ensure all connections are tightly secured before each use.

 

Level the stand with the adjustable feet prior to each use.

 

 Check  for  gas  leaks  before  each  use—this  can  be  done  by 
applying soapy water and looking for bubbles.

 

 This  system  gets  dangerously  hot  while  in    use.  Use  well-
insulated protective gloves, clothing and boots during operation 
for  protection  from  hot  surfaces  or  splatter  from  hot  liquids. 
Safety  goggles  are  also  recommended  to  protect  you  from 
splatter.

 

 Keep a fire extinguisher nearby at all times when operating the 
Center of Gravity™.

 

 Use a pump or gravity to move hot liquids from or into each 
brewing vessel.

 

Allow the system to cool to 100°F (38°C) before moving or storing.

Product

Center of Gravity™

Maximum Batch Size

10 Gallons

Burner Output

54,000 BTUs

Load Capacity (One Burner)

125 lbs.

Weight

90 lbs.

Load Capacity (Full System)

300 lbs.

Footprint

38” x 38”

Maximum Kettle Diameter

16.5”

Height of Bottom Burner

26.5”

Maximum Kettle Height

19”

Height of Middle Burner

44.75”

Base Material

Powder-Coated Steel

Height of Top Burner

63”

Burner Frame Material

High-Temp-Industrial-Paint-Coated Steel

Full Height

63.5”

Burner Material

Cast Iron

Packs into Hockey Bag

35”L x 17”W x 18”H

Propane Line Material

Rubber with Brass Connections

WARNING

READ AND UNDERSTAND BEFORE USING THIS PRODUCT

Reviews: