TECHNICAL DETAILS
–
Do not leave this system unattended while any burner is lit or
while heating.
–
Monitor the system when hot and after use (temperatures
above 100°F/38°C). Heated liquid and equipment can remain at
scalding temperatures long after the boil has ended and burners
have been shut off.
–
Do not exceed 125 lbs. per burner assembly or 300 lbs. for the
full system.
–
Do not use this system for heating oil or grease.
–
Keep children, pets and unauthorized persons away from the
Center of Gravity™ at all times.
–
Always operate the system on a level, stable, noncombustible
surface such as brick or concrete. Surfaces not suitable for use
include wood, asphalt or plastic which may burn, blister or melt.
–
This system is for outdoor use only. Do not use in a building,
garage, tent or any other enclosed area. Do not use in or on a
recreational vehicle or boat.
–
Do not locate this system under any overhead construction.
Keep a minimum clearance of 10 ft. (3.05m) from the sides,
front and back of the burner to any construction. Keep the area
clear of any combustible material. Do not use on or under any
apartment or condo balcony or deck.
–
Do not allow the flame to roll past the bottom of the brew kettle.
–
Do not install casters or wheels on the Center of Gravity™.
–
Never lift or move a full kettle of water onto or off of the Center
of Gravity™.
–
Only use the propane tank valve as the gas shutoff. Do not use
the regulator or needle valves.
–
A 20-pound (9 kg) propane cylinder should be used with this
burner. The LP-gas supply cylinder used must have a protective
collar and must be constructed and marked in accordance with
the specifications for LP-gas cylinders of the U.S. Department
of Transportation (DOT), cylinders, spheres and tubes for the
transportation of Dangerous Goods. Do not store a spare LP-gas
cylinder indoors, or under or near the Center of Gravity™. Never
fill the cylinder beyond 80% full. For proper vapor withdrawal,
the 20 lb. (9 kg) cylinder should be used in the proper upright
position. Cylinder must be turned off while not in use. Failure
to follow these instructions and warnings could result in fire or
explosion which could cause property damage, personal injury
or death.
–
Keep the gas supply hose away from heated surfaces at all times.
–
Ensure all connections are tightly secured before each use.
–
Level the stand with the adjustable feet prior to each use.
–
Check for gas leaks before each use—this can be done by
applying soapy water and looking for bubbles.
–
This system gets dangerously hot while in use. Use well-
insulated protective gloves, clothing and boots during operation
for protection from hot surfaces or splatter from hot liquids.
Safety goggles are also recommended to protect you from
splatter.
–
Keep a fire extinguisher nearby at all times when operating the
Center of Gravity™.
–
Use a pump or gravity to move hot liquids from or into each
brewing vessel.
–
Allow the system to cool to 100°F (38°C) before moving or storing.
Product
Center of Gravity™
Maximum Batch Size
10 Gallons
Burner Output
54,000 BTUs
Load Capacity (One Burner)
125 lbs.
Weight
90 lbs.
Load Capacity (Full System)
300 lbs.
Footprint
38” x 38”
Maximum Kettle Diameter
16.5”
Height of Bottom Burner
26.5”
Maximum Kettle Height
19”
Height of Middle Burner
44.75”
Base Material
Powder-Coated Steel
Height of Top Burner
63”
Burner Frame Material
High-Temp-Industrial-Paint-Coated Steel
Full Height
63.5”
Burner Material
Cast Iron
Packs into Hockey Bag
35”L x 17”W x 18”H
Propane Line Material
Rubber with Brass Connections
WARNING
READ AND UNDERSTAND BEFORE USING THIS PRODUCT