Specifications & Performance Claims
PERFORMANCE CLAIMS
Contaminant
Influent Challenge Level
Maxiumum Allowable
Product Water Level
Barium
10 ±10% mg/L
2.0 mg/L
Radium 226/228
25 pCi/L
5 pCi/L
Substance
Influent Challenge Level
Reduction Requirement
Chlorine
2.0 ±10% mg/L
50%
Questions?
Contact us at:
or visit
www.northstarwater.com
SPECIFICATIONS
Model NSCWC
Model Code
nSAC
Rated Softening Capacity (Grains @ Salt Dose)
14,000 @ 2.9 lbs.
29,800 @ 9.3 lbs.
35,600 @ 15.6 lbs.
Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose)
4,780 @ 2.9 lbs.
Water Used During Regeneration @ Minimum Salt Dose
3.7 gal. / 1,000 grains
Total Water Used Per Regeneration @ Maximum Salt Dose
58.6 gallons
Rated Service Flow Rate
8.0 gpm
Amount of High Capacity Ion Exchange Resin
0.98 cu. ft.
Amount of Activated Carbon
0.25 cu. ft.
Pressure Drop at Rated Service Flow
14.4 psig
Intermittent Flow Rate @ 15 psi
j
8.2 gpm
Water Supply Max. Hardness
100 gpg
Water Supply Max. Clear Water Iron
3 ppm
k
Water Supply Pressure Limits (minimum / maximum)
20 - 125 psi (138 - 862 kPa)
l
Water Temperature Limits (minimum / maximum)
40 - 120 °F (5 - 49 °C)
Minimum Water Supply Flow Rate
3 gpm (11.4 lpm)
Maximum Drain Flow Rate
2.0 gpm (7.6 lpm)
0.50 ppm
0.75 ppm
Rated Capacity at Chlorine Concentration
m
of: 1.0 ppm
1.5 ppm
2.0 ppm
2,280,000 gal. (8,630,000 liters)
n
1,520,000 gal. (5,750,000 liters)
n
1,140,000 gal. (4,310,000 liters)
n
760,000 gal. (2,870,000 liters)
n
570,000 gal. (2,150,000 liters)
n
j
Intermittent flow rate does not represent the maximum service flow rate used for determining
the softener’s rated capacity and efficiency. Continuous operation at flow rates greater than the
service flow rate may affect capacity and efficiency performance.
k
Capacity to reduce clear water iron is substantiated by laboratory test data. State of Wisconsin
requires additional treatment if water supply contains clear water iron exceeding 5 ppm.
l
Canada working pressure limits: 1.4 - 7.0 kg/cm
2
.
m
Typical residential chlorine concentration is 0.5 to 1.0 ppm.
n
From independent laboratory test data.
This system conforms to NSF/ANSI Standards 42 & 44 for the specific performance claims as
verified and substantiated by test data.
Variable Salt Dose:
The salt dose is selected by the electronic controls at regeneration time
based on the amount needed.