GENERATOR FEATURES

Reference 1 - Air Cleaner.  

Refer to your Kohler

engine manual for air cleaner care.

Reference 2 - Circuit Breakers.  

This portable

single phase generator  has  1  - 60 amp  (A)  thermal
magnetic 2 pole breaker, 1 - 30 amp  (A)  thermal
magnetic 2 pole breaker 1 - 30 amp (A) push to reset
circuit breaker, and 2 - 20 amp (A) push to reset  circuit
breakers. Circuit breakers protect against  electrical
overloads.

Reference 3 - 120/240V Receptacle.  

This

receptacle is a 120/240V 60A  NEMA  14-60R
receptacle.  This receptacle accepts a NEMA plug
number 14-60P, which is supplied with the generator.
Use this receptacle if installing a transfer  switch.
Compatible with Gentran transfer switch, item
#164117.

Reference 4 - 120/240V Tw istlock Receptacle.

This twistlock is a 120/240V 30A NEMA L14-30R
receptacle.  This receptacle accepts a NEMA plug
number L14-30P, which is supplied with the generator.

Reference 5 - 120V Twistlock Receptacle.  

This

twistlock is a 120V 30A NEMA L5-30R receptacle.
This receptacle accepts a NEMA plug number  L5-30P,
which is supplied with the generator.

Reference 6 - 120V Receptacle.  

The generator

has a control panel with two duplex (two receptacles in
a common housing) receptacles. Each duplex is  a  120
volt (V)  20 amp (A) straight blade  receptacle,  National
Electrical Manufacturer’s Association (NEMA) number
5-20R.  This receptacle accepts NEMA plug numbers
5-15P and 5-20P.    Each duplex is  capable of drawing
20A at 120V.

ALWAYS

 use grounded male plugs.  The neutral

line of the generator is mechanically grounded  to  the
frame.  Matching NEMA male plugs must always be
used.

 

WARNING

 Contact a licensed electrician

to wire electrical plugs and/or  cordsets.    Improper
wiring could result in a fire or electrical shock.

Reference 7 - Oil Drain Valve. 

Refer to your

Kohler engine manual for  oil  change
recommendations.

Reference 8 - Vibration Isolation Mounts.  

The

engine and generator head are mounted on  rubber
cylinders  that absorb most  of the  engine  vibration.
This feature eliminates the tendency of the  machine  to
“walk” which is common in engine powered equipment.

Reference 9 - Starting/Stopping Instructions.
Reference 10 - Wheel Kit.  

Heavy duty wheel kit

(Item # 165919).

Reference 11 - 10.0 Gallon Gas Tank.   

Large

tank allows for extended run capabilities.  

Alw ays

allow room for gasoline expansion by not filling the  gas
tank completely full.

Reference 12 - Engine Key.  

The engine key

switch is located on the front of the engine.  Always
locate this switch and be familiar with its location
before operating the generator.

Reference 13 - Choke Lever.  

Used during  cold

starts.  Refer to  the  starting/stopping instructions    and
the Kohler Command 25 engine manual for usage.

Reference 14 - Muffler and Spark Arrestor.
Reference 15 - Oil Filter.

   Kohler oil filter  number

12-050-01 or equivalent.

Reference 16 - Battery Box and Battery.

Battery is shipped without electrolyte.  Fill each battery
cell to the fill line  with locally  purchased electrolyte
(sulfuric acid and  water).

 

WARNING

 Sulfuric acid is a corrosive

poison.  Avoid contact with skin, eyes or clothing.

Reference 17 - Gas Line Valve.   

The generator

tank has an ON-OFF valve mounted underneath the
tank.  Always keep this valve closed when the
generator is not in use.

Reference 18 - Generator Head.  

The electricity

producing part of  the generator.

Reference 19 - Gas Drain Valve.  

The generator

is equipped with a unique feature.  A gas drain valve is
installed to drain gasoline from  the  tank  without
disconnecting the gas line feeding the engine.  This
valve is intended to be used to drain gas prior to
extended periods of non  use.   It is  recommended that
if the period of non use is longer than 30 days,  the gas
should be drained, and the engine  run  until  all  the gas
is evacuated from the carburetor.  ALWAYS make
sure this valve is closed prior to filling the gas tank.

Reference 20 - Gas Cap w ith Gauge.   

The gas

cap is extra large, creating a large hole for refilling and
a comfortable  grip.

 

You can always monitor the fuel

level without removing the cap by using the fuel level
indicator built into the gas cap.

Low  Oil Shutdow n.  

The Kohler  engine is

protected against damage resulting from low oil level.
As the oil falls below the safe level,  the engine
automatically shuts off (the engine stop switch  remains
in the on position).  The engine will not start until the
oil is refilled to above the safe level.

             INTRODUCTION

Before starting your generator,  thoroughly  study

the instructions and cautions in this manual to assure
you are fully acquainted with the operation of all
components of this generator. Proper preparation,
operation and maintenance will  result in  operator
safety,  best  performance and  long life of the  generator.
For detailed engine operation and maintenance always
refer to the Kohler engine owner’s manual furnished
with the  generator.

North Star is constantly improving its  products.

The specifications outlined herein are subject  to
change without prior notice  or  obligation.   The
purchaser and/or user assumes  liability  of  any
modification and/or alterations on this equipment from
original design and manufacture.

Before using, the user shall determine the

suitability of this product  for its  intended use  and
assumes liability therein.

Summary of Contents for 15000 PPG

Page 1: ...EL 15000 PPG ITEM 165925 Professional Portable Generator M165925A OWNER S MANUAL 00211 Shown with Wheel Kit Item 165919 Any Questions Comments or Problems Call Customer Service at 1 800 270 0810 Hours...

Page 2: ...r North Star Pro Series Generator IMPORTANT Make certain the operator Reads and understands the manuals pertaining to this machine Is instructed in safe and proper operation of this machine NOTICE K B...

Page 3: ...y 2 1 US quarts with filter Starting Method Electric start 120V Receptacles 2 20 Amp A duplex NEMA 5 20R 30 Amp A twistlock NEMA L5 30R 120 240V Receptacles 30 Amp A twistlock NEMA L14 30R 60 Amp A st...

Page 4: ...240V 60A Receptacle 13 Choke 4 120 240V 30A Twistlock Rec 14 Muffler Spark Arrestor 5 120V 30A Twistlock Rec 15 Oil Filter 6 120V 20A Duplex Rec 16 Battery Box Battery 7 Oil Drain Valve 17 Gas Line Va...

Page 5: ...g the generator Reference 13 Choke Lever Used during cold starts Refer to the starting stopping instructions and the Kohler Command 25 engine manual for usage Reference 14 Muffler and Spark Arrestor R...

Page 6: ...njury to people NEVER touch hot muffler hot exhaust manifold or engine cooling fins ALWAYS remove all oil or gasoline deposits and accumulated dirt from generator and immediate area Keep generator hea...

Page 7: ...Cap or Split Phase SP type The following chart shows the approximate current required to start and run various types and sizes of 120 volt 60 cycle electric motors under various conditions 120V 60 Hz...

Page 8: ...damaged parts or loose or missing nuts and bolts If the aforementioned problems occur call Customer Service at 1 800 270 0810 GROUNDING All units must be grounded Drive a 3 4 or 1 copper pipe or rod i...

Page 9: ...s revolving field and synchronous type with one sealed radial roller bearing The rotor of the generator head is directly connected to the engine crank shaft and the stator is rigidly coupled to the en...

Page 10: ...ine speed too high b Voltage regulator out of adjustment a Bring generator to a qualified technician for adjustment b Bring generator to a qualified technician for adjustment Generator overheating a G...

Reviews: