Configuring DIP switch settings and definitions
101
R2MFC Media Bay Module Installation and Configuration Guide
R2 line signaling
Brazil Config 2 R2 signals are according to CCITT standard. See
Table 37
for the Brazil Config 2
R2 signal definitions.
Note:
CD bits are not used. They are set to
01
in transmit direction, and are ignored in receive direction.
MFC Register Signaling
MFC signal definitions depends on the stage and the direction of the call, there are four tables of
15 signals each: the first stage uses
I
signals forward and
A
signals backward, and the second stage
uses
II
signals forward and
B
signals backward. The meaning of the signals can also be different
when being transmitted or received. Meanings of the MFC signals are configurable. MFC signal
tables are part of the country-specific parameters.
Table 38
shows the MFC signal configuration in the R2MFC MBM accessed through the CLI for
Brazil Config 2.
Table 39 on page 102
shows the MFC transmitted signal configuration in the
R2MFC MBM accessed through the CLI for Brazil Config 2. These values are preconfigured by
the faceplate DIP switches as shown in
Figure 30 on page 92
. See
Chapter 7, “Command Line
Interface (CLI),” on page 73
for information on the CLI.
Table 37
Brazil Config 2 R2 A/B signals
Forward
Backward
Signal
A
B
Signal
A
B
Idle
1
0
Idle
1
0
Seize
0
0
Seize acknowledge
1
1
Clear forward
1
0
Answer
0
1
Clear back
1
1
Block
1
1
Table 38
Interpretation of received MFC signals (Sheet 1 of 2)
Meaning
Signal
Meaning
Signal
Meaning
Signal
Meaning
Signal
FW_Digit_1
I_1
FW_Categ_1
II_1
BW_NextDig
A_1
BW_FreeCharge
B_1
FW_Digit_2
I_2
FW_Categ_2
II_2
BW_ReSend
A_2
BW_Busy
B_2
FW_Digit_3
I_3
FW_Categ_3
II_3
BW_BCateg
A_3
BW_B_Congest
B_3
FW_Digit_4
I_4
FW_Categ_4
II_4
BW_A_Congest
A_4
BW_B_Congest
B_4
FW_Digit_5
I_5
FW_Categ_5
II_5
BW_CategOrAni
A_5
BW_FreeNoChrg
B_5
FW_Digit_6
I_6
FW_Categ_6
II_6
BW_Illegal
A_6
BW_B_Congest
B_6
FW_Digit_7
I_7
FW_Categ_7
II_7
BW_Prev2Digit
A_7
BW_Unlocated
B_7
Summary of Contents for R2MFC
Page 12: ...12 NN40010 300 ...
Page 14: ...14 How to Get Help NN40010 300 ...
Page 20: ...20 Chapter 1 Getting started NN40010 300 NN40010 300 ...
Page 26: ...26 Chapter 2 Overview NN40010 300 ...
Page 72: ...72 Chapter 6 R2MFC MBM maintenance NN40010 300 ...
Page 90: ...90 Chapter 7 Command Line Interface CLI NN40010 300 ...
Page 108: ...108 Configuring DIP switch settings and definitions NN40010 300 ...
Page 110: ...110 Diagnostic and loopback DIP switch settings NN40010 300 ...
Page 112: ...112 MFC Signal Definitions NN40010 300 ...
Page 114: ...114 CLI Cable Pinout NN40010 300 ...