Reference list
The following are the references in this section:
•
Meridian Data Features: Traffic Engineering and Configuration
(553-2731-151)
•
Traffic Measurement: Formats and Output (553-2001-450)
•
Meridian Data Features: Operations and Tests (553-2731-300)
Allowable operating distances
An ADM, MCDS, AIM, or ASIM may be placed as far from its associated
data terminal as is consistent with EIA RS-232 lead specifications. This
separation distance is not absorbed in the following information.
Single wire gauge
The allowable operating distances between the SL-1 peripheral equipment
(DLC) and a data terminal/computer port or MCDS port when one wire gauge
is used are as follows:
Cable
PIC outside
PVC inside (Type D)
22 AWG
4000 ft (1219 m)
4000 ft (1219 m
1
3400 ft (1036 m)
2
24 AWG
3500 ft (1067 m)
2900 ft (884 m)
1
2000 ft (610 m)
2
1600 ft (488 m)
3
26 AWG
200 ft (610 m)
2000 ft (610 m)
1
1700 ft (518 m)
2
Note 1:
QPC311E or higher vintage with QMT7C/D, QMT8A, QMT12A, MCDS
Note 2:
QPC311C/D with QMT7C/D, QMT8A, QMT12A, MCDS
Note 3:
QMT7D operating limitation with Nortel Networks cable