42 Chapter 4 Configuring the Passport 8250 for operations
241-5101-200 R2.2
Setting the clocking scheme to External Primary
1
Display the clockconfig parameters:
clockconfig [set]
2
For External Primary Board Number, enter a board number.
3
For External Primary Port Number, enter a port number.
4
For External Secondary Board Number, press enter to accept the default
value and move to the next field.
5
For External Secondary Port Number, press enter to accept the default
value and move to the next field.
6
For Admin Reference Clock Source, enter 1 for ExternalPrimary:
Admin Reference Clock Source: Internal 1
Example
The following is an example of setting port 10 on service board 2 as the
primary port. The clocking scheme is set to ExternalPrimary.
Admin Reference
Clock Source
0 = Internal = The clock is
derived from the Passport
8250.
1 = External Primary = clock
derived from the primary port.
2 = External Primary Automatic
Switching = Clock derived from
the primary port. Switch to
secondary port if problem with
secondary port.
3 = External Secondary =
Clock is derived from the
secondary port.
The clock source.
Operational
Reference Clock
Source
Internal (default),
ExternalPrimary, and
ExternalSecondary.
The current clock
source.
Table 4 (continued)
Clockconfig command parameters
Parameter
Values
Definition
(Sheet 2 of 2)
Summary of Contents for Passport 241-5101-200
Page 1: ...Passport Installation Guide 241 5101 200...
Page 2: ......
Page 4: ......
Page 6: ...6 Publication history 241 5101 200 R2 2...
Page 10: ...10 Contents 241 5101 200 R2 2...
Page 20: ...20 Chapter 1 Passport 8250 241 5101 200 R2 2...
Page 54: ...54 Appendix B LEDs 241 5101 200 R2 2...
Page 60: ...60 Index 241 5101 200 R2 2...
Page 61: ......