Switch settings for printed circuit packs 2-48
August 2006
08.01
NTP 297-3601-316
For Generic 602.20
Note:
Settings: 1 = ON, 0 = OFF, - = NOT APPLICABLE.
CAUTION: Incorrect address settings may cause system problems and a serious
degradation of service. For example, duplicating an address setting across two
different NT3T72 packs will result in conflicts.
Table 2-AT:
NT3T72 I/O Bus Extender pack - S2 switch settings for pack versions AD and earlier
Type of Shelf
Pack Location
(bsp)
Switches
1
2
3
4
Control
CE 3 2
15
0
0
0
0
Control
CE 3 3
15
0
0
0
0
Network
CE 1 2
2/3
0
0
1
0
Network
CE 1 3
2/3
1
0
1
0
Network
CE 1 4
2/3
0
1
0
0
Network
CE 1 5
2/3
1
1
0
0
CPU/Network
CE 3
2
8 (J1T72A-1/B-1) or
7 (J1T72C-1)
0
0
0
0
CPU/Network
CE 3
3
8 (J1T72A-1/B-1) or
7 (J1T72C-1)
0
0
0
0
CPU/Network
CE 3
2
14/15 (J1T72B-1) or
13/14 (J1T72C-1)
0
1
0
0
CPU/Network
CE 3
3
14/15 (J1T72B-1) or
13/14 (J1T72C-1)
1
1
0
0
GPIO
CE 3 1
2/3
0
1
1
0
GPIO
CE 3 1
19/20
1
1
1
0
GPIO
CE 1 1
2/3
0
0
0
1
GPIO
CE 1 1
19/20
1
0
0
1
Table 2-AU:
NT3T72AD I/O Bus Extender pack - S3 switch settings
NT3T72
NT3T70
S3 Switch
All 3T72s are AD or higher.
BB or higher
down
All 3T72s are AD or higher.
BA or lower
up
All 3T72s are not AD or higher.
Do not care