NTP 297-3601-316
08.01
August 2006
For Generic 602.20
3-22 Switch settings for balance networks
Note 2: See Figure 3-4 for information about how to set the R1 and R2
potentiometers.
Note 1: Settings: 1 = ON, 0 = OFF
Note 2: See Figure 3-4 for information about how to set the R1 and R2
potentiometers.
Table 3-O:
QNB65B Balance Network - switch settings for 24-gauge end-section non-loaded cable without
impedance compensator at far end of cable
Length
Resistance
Capacitance
Ft X 1000
Meters
R1
R2
Capacitance
Value (
µ
F)
SR Switches
1
2
3
4
5
6-7
1829-2134
5.5
0
0.17
0
1
0
0
0
7-9
2134-2743
5.5
0
0.17
0
1
0
0
0
9-11
2743-3353
4
3
0.17
0
1
0
0
0
11-13
3353-3962
4
3
0.17
0
1
0
0
0
13-15
3962-4572
4
3
0.17
0
1
0
0
0
15-17
4572-5182
3.5
3
0.19
0
0
1
0
0
17-19
5182-5791
3.5
3
0.19
0
0
1
0
0
19-21
5791-6401
3.5
4.5
0.21
0
1
1
0
0
21-23
6401-7010
3.5
4
0.21
0
1
1
0
0
23-25
7010-7620
3.5
5
0.23
0
0
0
1
0
25-27
7620-8230
4
5
0.23
0
0
0
1
0
27-28
8230-8534
4
5
0.23
0
0
0
1
0
Table 3-P:
QNB65B Balance Network - switch settings for 26-gauge end-section non-loaded cable without
impedance compensator at far end of cable
Length
Resistance
Capacitance
Ft X 1000
Meters
R1
R2
Capacitance
Value (
µ
F)
SR Switches
1
2
3
4
5
6-7
1829-2134
7
5
0.15
1
0
0
0
0
7-9
2134-2743
6
4.5
0.15
1
0
0
0
0
9-11
2743-3353
5.5
6
0.15
1
0
0
0
0
11-13
3353-3962
5
7
0.15
1
0
0
0
0
13-15
3962-4572
5
7
0.15
1
0
0
0
0
15-17
4572-5182
5
4
0.17
0
1
0
0
0
17-19
5182-5791
5
4
0.17
0
1
0
0
0
19-21
5791-6401
5
8
0.19
0
0
1
0
0
21-23
6401-7010
5
6
0.19
0
0
1
0
0
23-25
7010-7620
5
5
0.19
0
0
1
0
0