Back Panel
This section describes the BayStack 410-24T switch back panel components
(
Figure 1-4
).
Descriptions of the back panel components follow the figure.
Figure 1-4.
BayStack 410-24T Switch Back Panel
This automatic process is a temporary safeguard only. If
the stack configuration loses power, the temporary base
unit will not power up as the base unit when power is
restored. For this reason, you should always assign the
temporary base unit as the base unit (set the Unit Select
switch to Base) until the failed unit is repaired or replaced.
Link
10 Mb/s port
speed indicator
Green
On
The corresponding port is set to operate at 10 Mb/s and
the link is good.
Green
Blinking
The corresponding port has been disabled by software.
Off
The link connection is bad or there is no connection to
this port.
Activity
Port activity
Green
Blinking
Indicates network activity for the corresponding port. A
high level of network activity can cause the LEDs to
appear to be on continuously.
Table 1-1.
BayStack 410-24T Switch LED Descriptions
(continued)
Label
Type
Color
State
Meaning
Cascade Module
1
2
3
1
2
3
= AC power receptacle
= RPSU connector
= Cascade Module Slot
BS41004A
100-240V~
47-63HZ~
1.5A-600ma
Redundant Power