background image

  5

    Annex Communications Server R7.1B and Annex Host Tools R14.2 Release Notes

302566-A  Rev. 00

TCP keepalive Timers 

Three new tcp_keepalive parameters have been added for the Annex, 
ports and printer. The Annex parameter is the default for all TCP 
connections to or from the Annex. The default setting is 120 minutes 
(per RFC specifications). It is settable from 1 to 255 minutes. This 
parameter is read only on boot-up, so you need to reboot the Annex 
if you want to change it. The port parameter is the default for TCP 
connections to or from a given port. If it is set to zero, it defaults to 
the value of the annex tcp_keepalive parameter.

The printer parameter is the default for TCP connections to a given 
printer port. If it is set to zero, it defaults to the value of the annex 
tcp_keepalive

 parameter.

The Annex also does 10 retries at 75 second intervals. So this time 
must be added to the tcp_keepalive setting. For example, if the timer 
is set to 5 (5 seconds), the maximum time would be approximately 
17.5 minutes.

Year 2000 Compliance

The R7.1B release of software is Year 2000 Compliant for Micro Annex 
ELS. The R7.1 embedded image is compliant on a self boot only model 
(no host tools) or in conjunction with the R14.2.24 host tools. For more 
information, refer to SPR 11150 in the 

Problems Resolved with this 

Release

 section.

Supported Platforms

The Distribution media contains binary files for most of the supported 
platforms. When the script detects that there are binary files for the 
host operating system, it gives you the option of installing the binary 
files or loading the source code and compiling the software at a later 
time. If there are no binary files available, the script loads the source 
code and uses an available compiler on the host system to build the 
image. If the script does not identify a compiler on your system, it 
ends the installation session.

Summary of Contents for Annex Host Tools R14.2

Page 1: ...Resolved with this Release New Features printer_crlf Epson printers monitor pin 14 of the parallel port to decide how to handle CR If pin 14 is high the printer performs a CR If pin 14 is low the prin...

Page 2: ...an quote a portion of the path that should not be decomposed For example this that theother edu decomposes into this that theother edu and that theother edu When these paths are added the list is chec...

Page 3: ...n is enabled the Annex always requests for compression and always accepts requests for compression If allow_compression is disabled the Annex never requests for compression and always rejects requests...

Page 4: ...nes is set to flow_control or to both enables both in band XON XOFF and out of band CTS RTS flow control on the Annex III and Micro Annex CD180 serial communicationschip Thesemethodsofflowcontrolarein...

Page 5: ...es at 75 second intervals So this time must be added to the tcp_keepalive setting For example if the timer is set to 5 5 seconds the maximum time would be approximately 17 5 minutes Year 2000 Complian...

Page 6: ...ads its image into flash from any other host and the Annex correctly boots from an Annex boot server R7 1 can not fit into half megabyte of FLASH in self boot units Table 1 Operating System Support Op...

Page 7: ...equest The work around is to insure that the rs232AsyncPortAutobaud set request is at the end of the set request packet or is alone in the set request Problems Resolved with this Release SPR 11150 The...

Page 8: ...not supported by the R10 0B release of software The Annex Administrators Guide for Unix that is sent with this release of software mentions several features which are not present in the R10 0B softwa...

Reviews: