background image

1

302566-A  Rev. 00

Annex Communications Server R7.1B and

Annex Host Tools R14.2 Release Notes

These release notes apply to the following:

The Remote Annex Operational Code Version R7.1

The Annex Host Tools Version R14.2.24

Annex Manager R1.1

Included in these Release Notes are the following topics:

New Features

Special Considerations

Supported Platforms 

Known Problems/Limitations 

Problems Resolved with this Release

New Features

printer_crlf

Epson printers monitor pin 14 of the parallel port to decide how to 
handle CR. If pin 14 is high, the printer performs a CR. If pin 14 is 
low, the printer performs a CR/LF. The default value is Y and enables 
the converting of <CR> to <CR><LF>. The value of N disables the 
parameter so the printer does not add a <LF>.

Telnet Connectivity to Parallel Ports

Parallel ports now appear on the network as Annex TCP ports 5901-
5999 and 7901-7999. This means that rtelnet can access the parallel 
ports; aprint is no longer necessary to use the parallel ports.

Summary of Contents for Annex Host Tools R14.2

Page 1: ...Resolved with this Release New Features printer_crlf Epson printers monitor pin 14 of the parallel port to decide how to handle CR If pin 14 is high the printer performs a CR If pin 14 is low the prin...

Page 2: ...an quote a portion of the path that should not be decomposed For example this that theother edu decomposes into this that theother edu and that theother edu When these paths are added the list is chec...

Page 3: ...n is enabled the Annex always requests for compression and always accepts requests for compression If allow_compression is disabled the Annex never requests for compression and always rejects requests...

Page 4: ...nes is set to flow_control or to both enables both in band XON XOFF and out of band CTS RTS flow control on the Annex III and Micro Annex CD180 serial communicationschip Thesemethodsofflowcontrolarein...

Page 5: ...es at 75 second intervals So this time must be added to the tcp_keepalive setting For example if the timer is set to 5 5 seconds the maximum time would be approximately 17 5 minutes Year 2000 Complian...

Page 6: ...ads its image into flash from any other host and the Annex correctly boots from an Annex boot server R7 1 can not fit into half megabyte of FLASH in self boot units Table 1 Operating System Support Op...

Page 7: ...equest The work around is to insure that the rs232AsyncPortAutobaud set request is at the end of the set request packet or is alone in the set request Problems Resolved with this Release SPR 11150 The...

Page 8: ...not supported by the R10 0B release of software The Annex Administrators Guide for Unix that is sent with this release of software mentions several features which are not present in the R10 0B softwa...