Install ISDN BRI hardware
553-3901-200
Standard 7.00
January 2002
Connect Meridian 1 modules to the MDF
Meridian 1 modules connect to the MDF using NE-A25B cables with 50-pin
D-type male connectors on each end. One end of the cable plugs into the I/O
panel at the rear of the Meridian 1 module and the other end plugs into the
MDF.
Figure 6 shows the cable connection between the Meridian 1 and the MDF.
1
Determine the number of NE-A25B cables needed to connect one
module to the MDF.
2
Label each end of the cable specifying the module number, the
connector name (A, B, C), and the card type (SILC or UILC).
3
Plug one end of a cable into the appropriate connector on the I/O panel
at the rear of the Meridian 1 module. Plug the other end of the cable
into the corresponding connector on the MDF.
4
Properly identify cables on the MDF. For example, plug the cable into
connector A on the I/O panel and into the connector labeled A on the
MDF if an SILC or UILC is installed in slot 0 of an IPE module.
5
Repeat steps 2 through 4 for all cables in that module.
6
Repeat steps 1 through 5 for all modules containing SILCs and/or
UILCs.
7
Lay all the cables neatly and fasten them with cable ties.
8
Label the MDF, as necessary, using Table 2 through Table 5.
—————————— End of Procedure ——————————
Summary of Contents for 553-3901-200
Page 2: ......
Page 4: ...Page 4 of 46 553 3901 200 Standard 7 00 January 2002...
Page 6: ...Page 6 of 46 Contents 553 3901 200 Standard 7 00 January 2002...
Page 8: ...Page 8 of 46 About this document 553 3901 200 Standard 7 00 January 2002...
Page 12: ...Page 12 of 46 Preinstallation preparation 553 3901 200 Standard 7 00 January 2002...
Page 46: ...Page 46 of 46 Install ISDN BRI hardware 553 3901 200 Standard 7 00 January 2002...
Page 47: ......