Known issues
43
Item
Description
6
On the 5530-24TFD, the following (NT-OCP) SFPs cannot be inserted side by
side (that is, in neighboring slots) because of the SFP size. The SFPs are listed
as manufacturer part number/Nortel part number:
•
TRP-G1H5BC470N4 / AA1419025
•
TRP-G1H5BC490N4 / AA1419026
•
TRP-G1H5BC510N4 / AA1419027
•
TRP-G1H5BC530N4 / AA1419028
•
TRP-G1H5BC550N4 / AA1419029
•
TRP-G1H5BC570N4 / AA1419030
•
TRP-G1H5BC590N4 / AA1419031
•
TRP-G1H5BC610N4 / AA1419032
•
TRP-G1H7BC470N4 / AA1419033
•
TRP-G1H7BC490N4 / AA1419034
•
TRP-G1H7BC510N4 / AA1419035
•
TRP-G1H7BC530N4 / AA1419036
•
TRP-G1H7BC550N4 / AA1419037
•
TRP-G1H7BC570N4 / AA1419038
•
TRP-G1H7BC590N4 / AA1419039
•
TRP-G1H7BC610N4 / AA1419040
7
While downloading the image file, you may receive the following error message:
"Error reading image file."
Workaround: Typically, this issue can be resolved by simply restarting the image
download. If this does not resolve the issue, Nortel recommends that you try an
alternate method to download the image to the switch (that is, the Web Interface).
8
When a remote server log is configured and the remote logging is enabled, the
CLI audit task sends messages to the syslog server regardless of the logging
level.
9
The IPFIX sampling data rate cannot be changed because of a related hardware
limitation.
Nortel Ethernet Routing Switch 5000 Series
Release Notes — Release 6.0
NN47200-400
04.01
Standard
6.0
12 December 2008
Copyright © 2008., Nortel Networks
.
Summary of Contents for 5000
Page 1: ...Nortel Ethernet Routing Switch 5000 Series Release Notes Release 6 0 NN47200 400 ...
Page 4: ......