Installing and Operating Passport ARN Routers
B-18
114200-E Rev 00
7.
Name and save the configuration file.
The script begins to test the configuration on the new IP interface
(Figure B-2)
.
Figure B-2.
Starting the IP Interface Test
8.
To continue the IP configuration test, enter the IP address for the Site
Manager workstation.
To cancel the test, enter
q
.
9.
Choose whether you want to configure another module/port.
If you enter
n
, (to stop configuring modules/ports), the Technician Interface
prompt appears. If you enter
y
, you return to Step 6 of this procedure.
10.
When the Technician Interface prompt reappears, enter
logout
to exit the
Technician Interface.
When the router creates and tests the configuration, it starts using the
configuration information you entered. Refer to
Configuring Passport Remote
Access
to configure the router using Site Manager.
Testing local IP interface
ping -IP 192.32.00.000 -r5
IP ping: 192.32.00.000 is alive (size - 16 bytes)
IP ping: 192.32.00.000 is alive (size - 16 bytes)
IP ping: 192.32.00.000 is alive (size - 16 bytes)
IP ping: 192.32.00.000 is alive (size - 16 bytes)
IP ping: 192.32.00.000 is alive (size - 16 bytes)
This test attempts to ping the Site Manager workstation.
NOTE: If routing has not yet converged, an attempt
to ping the Site Manager workstation may fail. If
this happens, you may either enter a new IP address or
quit and wait a short period of time and try again from
the TI command line.
Type q<return> to cancel this test.
Enter IP address of Site Manager workstation: