. Install
a
dedicated
circuit breaker in accordance with the related laws and regulations and
standards.
ķ
. The
power
source capacity must be the sum of the air conditioner current and the current of
other electrical appliances.
ĸ
. When
the
voltage
is
low, the air conditioner will not run properly. Supply voltage will need to be
adjusted..
4.7.2 Electrical Wiring
(1). For solid core wiring (Fig. 4.36)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the
insulation about 25mm (1inch).
2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
3). Using pliers, bend the solid wire to form a loop suitable for the terminal
screw.
4). Shape the loop wire properly, place it on the terminal board and tighten
securely with the terminal screw using a screwdriver.
(2). For strand wiring (Fig. 4.36)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the
insulation about 10mm (3/8inch).
2). Using a screwdriver, remove the terminal screw (s) on the terminal board.
3). Using a round terminal fastener or pliers, securely clamp a round terminal
to each stripped wire end.
4). Position the round terminal wire, and replace and tighten the terminal screw
with a screwdriver (Fig. 4.37).
Fig. 4.36