background image

7

CoMPoNENt loCAtioNS FoR NoN-CoNdENSiNG tYPE FURNACES

Single Stage Models

2- Stage Models

Blower

Door

Switch

Burner

Assembly

Flame Sensor

Gas

Manifold

Gas Valve

Igniter

Inducer 

Assembly

Pressure

Switch

Roll-Out

Switch

Transformer

Blower 

Assembly

Furnace

Control

Board

Main Air

Limit Switch

Comb

ustion 

Tube

Gas

Manifold

Gas Valve

Inducer

Assembly

Pressure

Switch

Transformer

Blower Assembly

(behind blower panel)

Burner

Assembly

Flame

Sensor

Roll-Out

Switch

Igniter

Main Air

Limit Switch

Blower

Door Switch

(behind blower panel)

*SA 80+ 

Upflow / Horizontal Gas Furnace

*SK 80+ 

Downflow Gas Furnace

Furnace

Control

Board

12

34

56

78

Motor Choke

(C & D cabinets only)

Motor Control

Board

Motor

Control Box

Blower

Door

Switch

Burner

Assembly

Flame Sensor

Gas Manifold

Gas Valve

Igniter

Inducer 

Assembly

Pressure

Switch

Roll-Out Switch

Transformer

Blower

Assembly

Furnace

Control Board

Main Air

Limit Switch

1

2

3

4

5

6

7

8

Furnace

Control

Board

Comb

ustion 

Tube

Gas Manifold

Gas Valve

Inducer

Assembly

Pressure

Switches

Transformer

Burner

Assembly

Flame

Sensor

Roll-Out

Switch

Igniter

Main Air

Limit Switch

Blower

Door Switch

(behind blower panel)

Motor Choke

(C & D cabinets only)

Motor

Control

Board

Blower Assembly

(behind blower panel)

*TA 80+ 

Upflow / Horizontal Gas Furnace

*TK 80+ 

Downflow Gas Furnace

Summary of Contents for FG7MQ

Page 1: ...perty damage Installation and service must be performed by a qualified installer service agency or the gas supplier Donotstoreorusegasolineorotherflammable vapors and liquids in the vicinity of this o...

Page 2: ...2...

Page 3: ...ategory I Non Condensing Furnaces 6 Category IV Condensing Furnaces 6 FILTER 6 THERMOSTAT 6 FURNACE LOCATION 6 COMPONENT LocationS for Non Condensing Type Furnaces 7 COMPONENT LocationS for Condensing...

Page 4: ...bedroomsineachsleeping area CO detectors should be certified to the most recent requirements of the UL IAS OR CSA Standard and should be installed operated and maintained in accordancewiththedetectorm...

Page 5: ...ids A fire or explosion may result causing property damage personal injury or loss of life Failure to follow the safety warnings exactly could result in serious injury death or property damage The fur...

Page 6: ...ner must make sure the condensate drain lines do not become blocked pinched or crushed If the furnace is installed in an area where temperatures fall below freezing special precautions must be made fo...

Page 7: ...izontal Gas Furnace SK 80 Downflow Gas Furnace Furnace Control Board 1 2 3 4 5 6 7 8 Motor Choke C D cabinets only Motor Control Board Motor Control Box Blower Door Switch Burner Assembly Flame Sensor...

Page 8: ...Board Main Air Limit Switch Transformer Roll Out Switch SC 92 1 Upflow Horizontal Gas Furnace SL 92 1 Downflow Gas Furnace Blower Assembly behind blower panel Burner Assembly Finish Flange Flame Senso...

Page 9: ...Switch behind blower panel Motor Choke C D cabinets only Gas Manifold Gas Valve Igniter Inducer Assembly Inducer Limit Switch Main Air Limit Switch Furnace Control Board Motor Control Board Pressure...

Page 10: ...e before turning off the electrical service NOTE Your furnace may be equipped with one of three types of gas valves Remove the door panel from the front of the furnace and determine which valve type m...

Page 11: ...cured without holes or corrosion Any corroded section of vent pipe must be replaced and any obstruction or blockage must be removed by the technician Flue passageways the vent system and the burners s...

Page 12: ......

Page 13: ...n utiliser aucun t l phone dans le b timent vacuer l immeuble imm diatement Appeler imm diatement le fournisseur de gaz en employant le t l phone d un voisin Respecter les instructions du fournisseur...

Page 14: ...2...

Page 15: ...densation 6 G n rateurs d air chaud de cat gorie IV 6 condensation 6 FILTRE 6 THERMOSTAT 6 Emplacement du G N RATEUR D AIR CHAUD 6 Emplacement des COMPOSANTS pour g n rateurs d air chaud sans condensa...

Page 16: ...hambres coucher Les d tecteurs de monoxyde de carbone doivent tre homologu s en vertu des plus r centes exigences des normes UL IAS ou CSA et doivent tre install s utilis s et entretenus conform ment...

Page 17: ...ou des pertes de vie Le non respect desavertissementsdes curit pourraitentra nerdes blessuresgraves lamortoudesdommagesmat riels Le g n rateur d air chaud est con u pour avoir un certain d gagement au...

Page 18: ...n de s assurer que les conduites d coulement de condensat ne sont pas bouch es pinc es ou cras es Si le g n rateur d air chaud est install dans un endroit o les temp ratures chutent sous le point de c...

Page 19: ...d air chaud 1 2 3 4 5 6 7 8 trangleur de moteur armoires C et D seulement Tableau de commande de moteur Bo te de commande de moteur Commutateur de porte du souffleur Ensemble br leur D tecteur de flam...

Page 20: ...d air chaud au gaz flux descendant 92 1 SL Ensemble souffleur derri re le panneau de souffleur Ensemble br leur Bride de finition D tecteur de flamme Allumeur Commutateur de retour Robinet de gaz Tab...

Page 21: ...de gaz Robinet de gaz Allumeur Ensemble inducteur Commutateur de s curit d inducteur Commutateur de s curit d air principal Tableau de commande de g n rateur d air chaud Tableau de commande de moteur...

Page 22: ...chaud pour une r paration ou un entretien fermer le robinet de gaz aliment au g n rateur d air chaud avant de couper l alimentation lectrique REMARQUE Le g n rateur d air chaud peut tre dot d un de ce...

Page 23: ...tour du g n rateur d air chaud Il faut faire inspecter annuellement le syst me de ventilation du g n rateur d air chaud par un technicien en CVC agr Le conduit d vent doit tre inclin dans une pent asc...

Page 24: ...pecifications illustrations subject to change without notice or incurring obligations 07 15 O Fallon MO Nortek Global HVAC LLC 2015 All Rights Reserved Sp cificationsetillustrationssujettes changement...