refrigerant lines and drain line where required. 
Reinstall all inner and outer panels of the furnace/
air handler that were previously removed to 
install the indoor coil.

Refrigerant Charging —

 These indoor coils are 

not factory charged with refrigerant.

It will be necessary to evacuate the indoor coil 
and line set prior to charging. Refer to the outdoor 
unit installation manual for detailed charging 
instructions.

6.  MAINTENANCE AND SERVICE

 

WARNING:

Ensure that all electrical power to the 
furnace and outdoor (condensing) 
unit is off before performing any 
maintenance or service on the 
system.

To ensure optimum system performance and 
to minimize the possibility of equipment failure, 
the following periodic maintenance should be 
performed on the coil:

1.  The air filter installed with the system should 

be checked and cleaned or replaced twice 
per year.

2.  Check the coil, drain pan, and condensate 

drain line for cleanliness at the start of each 
heating and cooling season. Clean and 
remove any debris as required.

 

CAUTION:

Do not operate the system without 
having a suitable filter in place in 
the return air duct system. Always 
replace the filter with the same size 
and type.

Summary of Contents for C6B-T

Page 1: ...nd or furnace air h a n d l e r m a r k i n g s before proceeding with installation of the coil These instructions are primarily intended to assist qualified individuals experienced in the proper inst...

Page 2: ...2...

Page 3: ...Furnace Air Handler 4 Downflow Horizontal 4 3 Pressure Verification 4 4 Refrigerant Line Connections 5 5 Completing the Installation 5 Condensate Drain 5 Air Filters 5 Close off Plates and Panels 5 Re...

Page 4: ...when an add on coil is installed Refer to Coil Specifications for recommended CFM and allow for pressure drop across the coil and filters 2 COIL INSTALLATION Upflow Furnace WARNING Electricfurnacesma...

Page 5: ...the sensing bulb and the lineset braze joint before applying any heat 12 Braze the individual connections with dry nitrogenflowingthroughthejointtoeliminate internal oxidation and scaling 13 Fasten nu...

Page 6: ...ical power to the furnace and outdoor condensing unit is off before performing any maintenance or service on the system To ensure optimum system performance and to minimize the possibility of equipmen...

Page 7: ...17 1 2 17 1 2 17 1 2 17 1 2 17 1 2 23 1 2 23 1 2 23 1 2 23 1 2 27 27 27 27 27 HS Height of Suction Line in 15 1 2 15 1 2 15 1 2 15 1 2 15 1 2 15 1 2 21 1 2 21 1 2 21 1 2 21 1 2 25 25 25 25 25 Connect...

Page 8: ...Condensation Deflector 690071 Insulation Case Nut 606287 Distributor Figure 3 Condensation Deflector Positioning 708821D Replaces 708821C Specifications illustrations subject to change without notice...

Reviews: