6-050700 X2
21
212iLW & 242iLW Standalone Keypad
Installation & Programming Manual
Command/Action
Keys to Enter/Details
Command 60.
Add/Modify
Enhanced User
60 # user type # user location # code
✱
code
✱
(codes can be from 1 to 10 digits in length)
User Types
0 – Toggle User
1 – Standard User
3 – Lockout User
5 – Single Use Code
7 – Emergency User
8 – Duress User
9 – Two-Part User Type A
10 – Two-Part User Type B
Toggle User
A toggle user latches the virtual lock output.
Standard User
Activates the virtual lock output using the lock
duration programmed with Command 11.
Lockout User
This user type locks out users in user locations
higher than the lockout user when the lockout
user code is entered. For example, if the lockout
user is programmed for user 20, any user in
location 21 to 120 is locked out and their codes
no longer work to gain access. A lockout is
removed by entering the same lockout code. If
another lockout code in another user location is
entered, the lockout user location level is set to
the new lockout user location. The master code
and emergency users can’t be locked out. The
current lockout is cleared when program mode is
entered. “Lockout activated” is indicated by two
double beeps. “Lockout canceled” is indicated by
one double beep. “Access denied due to lockout”
is indicated by 1 long beep followed by 3 short
beeps. “User lockout” can be enabled or disabled
with Command 30.
Single Use Code
This code can only be entered once to gain
access using the lock virtual output. Once used,
this code is no longer active. A single use code
can be veri
fi
ed by entering
5 # code
✱
. If the
code is a single use code, the green LED
fl
ashes
for ½ a second. An “invalid code” is indicated by
3 quick beeps.