6-050700 X2
19
212iLW & 242iLW Standalone Keypad
Installation & Programming Manual
Command/Action
Keys to Enter/Details
Command 11.
Set
LOCK Time Duration
11 # time # 0 #
✱
✱
(time = 1 to 255 seconds)
Command 12.
Set
OUT2 Time Duration
12 # ttt # mmm #
✱
✱
To toggle, enter:
12 # 0 # 0 #
✱
✱
Command 13.
Set
OUT3 Time Duration
13 # ttt # mmm #
✱
✱
To toggle, enter:
13 # 0 # 0 #
✱
✱
Command 14.
Set
OUT4 Time Duration
14 # ttt # mmm #
✱
✱
To toggle, enter:
14 # 0 # 0 #
✱
✱
Command 15.
Set
OUT5 Time Duration
15 # ttt # mmm #
✱
✱
To toggle, enter:
15 # 0 # 0 #
✱
✱
Options:
ttt (time units)
Number of time units to operate OUTn when
valid PIN entered (1-255)
Examples:
12 # 1 # 10 #
(for 10 seconds)
(1 time unit multiplied by 10 seconds)
12 # 2 # 10 #
(for 20 seconds)
(2 time units multiplied by 10 seconds)
mmm (multiplier)
Number of seconds in each time unit (1-255)
Examples:
12 # 15 # 1 #
(for 15 seconds)
(15 time units multiplied by 1 second)
12 # 15 # 2 #
(for 30 seconds)
(15 time units multiplied by 2 seconds)
Command 44.
Set
Propped Door Time
44 # time # 0 #
✱
✱
Options:
time
Propped Door Time - rounded down to nearest
10’s of seconds; entered as 00, 10 through 990,
defaults to 30 seconds; entering a time of zero
disables the propped door function.
Command 45.
Set
Forced Door Time
45 # time # 0 #
✱
✱
Options:
time
Forced Door Time - rounded down to nearest
10’s of seconds; entered as 00, 10 through 990,
defaults to 10 seconds; entering a time of zero
latches the virtual forced door that can be cleared
with any valid PIN or by entering program mode.