22
TS571W Installation Instructions
TS571W Installation Instructions
23
This product has the ability of being control via a smart device (i.e. smartphone) with the addition of the MMS100 smart kit. Refer to
the instructions contained in the MMS100 kit or visit
for more information
AUTO CLOSE SETTING
Optional Smart Control Setup
●
The auto close timer is set to OFF
from the factory.
●
To set an auto close timer, use a
small flat head screw driver to
turn the auto close potentiometer
clockwise.
●
The timer can be set from
approximately 3 seconds to a
maximum of 120 seconds.
••
••
•••
••
••
••
••
●
If you have additional accessories
or external devices to install, see
the following page.
●
Unless you have additional
external accessories to install,
your gate operator installation is
now complete.
●
Please review the installation
checklist at the end of this
manual.
●
Use a phillips head screwdriver to
close the control box.
Step 1
Step 2
Wiring Accessories through Control Board Wiring Knockout
Carefully remove wiring
knockout plugs to insert
accessory wires.
Open the control box cover.
Close the control box cover.
Insert accessory wires
through the knockout and
route to the accessory
input terminals on the
control board. (See pg. 12)
ON/OFF Switch
Accessory Wires
(Photo beams, keypad, etc.)
Mighty Mule strongly recommends the use of additional obstruction detection devices however we do not endorse any specific brand
names. Only use products that are listed to be in compliance with any applicable UL safety standards and national and regional
codes.
PLEASE NOTE: Contact sensors, non-contact sensors, shadow loops, etc. are not included with this product. Refer to the sensor
manufacturer’s instructions for information about installing accessory devices.
The Mighty Mule ONLY accepts accessory devices with normally open dry contact outputs.
Connecting Additional Devices
WARNING
Make sure the operator power switch is turned OFF before connecting
ANY device wiring to the terminals of the controller. Unplugging the
transformer does not turn power to the operator off.