SWIMMING POOL HEAT PUMP TYPE PX
SWIMMING POOL HEAT PUMP TYPE PX
6
7
Alterations which serve the technological progress as well as errors excepted!
ORIGINAL MANUAL
NORSUP
WWW.NORSUP.EU
Alterations which serve the technological progress as well as errors excepted!
• An all-pole disconnection device which has at least
3mm clearances in all poles, and have a leakage
current that may exceed 10mA, the residual current
device (RCD) having a rated residual operating
current not exceeding 30mA, and disconnection
must be incorporated in the fixed wiring in
accordance with the wiring rules.
• Do not use means to accelerate the defrosting
process or to clean, other than those recommended
by the manufacturer.
• The appliance shall be stored in a room without
continuously operating ignition sources (for example:
open flames, an operating gas appliance or an
operating electric heater.)
• Do not pierce or burn.
• Appliance shall be installed, operated and stored in a
room with a floor area larger than X m
2
Be aware that
refrigerants may not contain an odour. The
installation of pipe-work shall be kept to a minimum
X m
2
Spaces where refrigerant pipes shall be
compliance with national gas regulations. Servicing
shall be performed only as recommended by the
manufacturer. The appliance shall be stored in a well-
ventilated area where the room size corresponds to
the room area as specified for operation. All working
procedure that affects safety means shall only be
carried by competent persons.
• Transport of equipment containing flammable
refrigerants Compliance with the transport
regulations Marking of equipment using signs
Compliance with local regulations Disposal of
equipment using flammable refrigerants
Compliance with national regulations Storage of
equipment/appliances The storage of equipment
should be in accordance with the manufacturer‘s
instructions. Storage of packed (unsold) equipment
Storage package protection should be constructed
such that mechanical damage to the equipment
inside the package will not cause a leak of the
refrigerant charge. The maximum number of pieces
of equipment permitted to be stored together will be
determined by local regulations.
CAUTION & WARNING
1. The unit can only be repaired by qualified installer
centre personnel or an authorized dealer (for
Europe market).
2. This appliance is not intended for use by persons
(including children) with reduced physical sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction concerning use of the
appliance by a person responsible for their safety.
(for Europe market) Children should be supervised
to ensure that they do not play with the appliance.
3. Please make sure that the unit and power connection
have good earthing, otherwise may cause electrical
shock.
4. If the supply cord is damaged, it must be replaced
by the manufacturer or our service agent or similarly
qualified person in order to avoid a hazard.
5. Directive 2002/96/EC (WEEE): The symbol depicting a
crossed-out waste bin that is underneath the appliance
indicates that this product, at the end of its useful life,
must be handled separately from domestic waste,
must be taken to a recycling centre for electric and
electronic devices or handed back to the dealer
when purchasing an equivalent appliance.
6. Directive 2002/95/EC (RoHs): This product is
compliant with directive 2002/95/EC (RoHs)
concerning restrictions for the use of harmful
substances in electric and electronic devices.
7. The unit CANNOT be installed near the flammable
gas. Once there is any leakage of the gas, fire can
be occur.
8. Make sure that there is circuit breaker for the unit, lack
of circuit breaker can lead to electrical shock or fire.
9. The heat pump located inside the unit is equipped
with an over-load protection system. It does not
allow for the unit to start for at least 3 minutes from
a previous stoppage.
10. The unit can only be repaired by the qualified
personnel of an installer center or an authorized
dealer. (for North America market)
11. Installation must be performed in accordance with
the NEC/CEC by authorized person only. (for North
America market)
12. USE SUPPLY WIRES SUITABLE FOR 75°C .
13. Caution: Single wall heat exchanger, not suitable for
potable water connection.
1. PREFACE
In order to provide our customers with quality,
reliability and versatility, this product has been made
to strict production standards. This manual includes
all the necessary information about installation,
debugging, discharging and maintenance. Please
read this manual carefully before you open or
maintain the unit. The manufacture of this product
will not be held responsible if someone is injured or
the unit is damaged, as a result of improper
installation, debugging, or unnecessary maintenance.
It is vital that the instructions within this manual are
adhered to at all times. The unit must be installed by
qualified personnel.
The unit can only be repaired by qualified installer
centre, personnel or an authorized dealer.
Maintenance and operation must be carried out
according to the recommended time and frequency,
as stated in this manual.
Use genuine standard spare parts only. Failure to
comply with these recommendations will invalidate
the warranty.
Swimming Pool Heat Pump Unit heats the swimming
pool water and keeps the temperature constant.
For split type unit. The indoor unit can be Discretely
hidden or semi-hidden to suit a luxury house.
Our heat pump has following characteristics:
1 Durable
The heat exchanger is made of PVC & Titanium tube
which can withstand prolonged exposure to
swimming pool water.
2 I nstallation flexibility
The unit can be installed outdoors or indoors.
3 Quiet operation
The unit comprises an efficient rotary/ scroll
compressor and a low-noise fan motor, which
guarantees its quiet operation.
4 Advanced controlling
The unit includes micro-computer controlling,
allowing all operation parameters to be set.
Operation status can be displayed on the LCD wire
controller. Remote controller can be chosen as
future option.
WARNING
It is recommended that your pool filtration pump and
your heat pump are wired independently. Wiring your
pool pump into the heat pump will result in your
filtration being switched off once the pool water has
reached temperature. Only wire the pool pump through
the heat pump if you have a pool pump for heating only
that is independent to your pool filtration system. Do
not use means to accelerate the defrosting process or
to clean, Other than those recommended by the
manufacturer. The appliance shall be stored in a room
without continuously operating ignition sources (for
example: open flames, an operating gas appliance or
an operating electric heater.) Do not pierce or burn.
Be aware that refrigerants may not contain an odour,
Appliance shall be installed, operated and stored in a
room with a floor area larger than X m
2
.
• This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children
without supervision.
• If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
• The appliance shall be installed in accordance with
national wiring regulations.
• Do not operate your air conditioner in a wet room
such as a bathroom or laundry room.
• Before obtaining access to terminals, all supply
circuits must be disconnected.
NOTE
The manufacturer may provide other suitable
examples or may provide additional information
about the refrigerant odour.