ATOM Ku BUC/SSPA
20W/25W/40W/50W
Revision A
908239
23
908239_rA - Operator Manual ATOM KU 20-
25-40-50W
Section 2.9
EMC
C
ONSIDERATIONS
For optimal EMC performance the following are recommended:
•
Use a high quality DC cable that’s shielded, grounded at both ends and not longer than
necessary for the application.
•
Use a high quality M&C cable that’s shielded, grounded at both ends and not longer than
necessary for the application.
•
Place two ferrite clamps such as Laird-Signal Integrity Products 28A3851-0A2 on the DC cable
closest to the ATOM.
•
Make sure the GND stud is connected according to national and local electrical codes.
•
If a serial to USB converter is used its case should be locally grounded if possible.
•
Use a high quality DC power source with the lowest possible voltage ripple and noise.