ATOM Ku BUC/SSPA
20W/25W/40W/50W
Revision A
908239
11
908239_rA - Operator Manual ATOM KU 20-
25-40-50W
Chapter 2
Installation and Interfaces
Section 2.1
O
VERVIEW
The unit has three connectors on the input side of the housing and one waveguide port on the output
side. The interface for these connectors is detailed in this document.
On the input side, there are the following connectors:
J1 – Female N-type L-band IF Input
J2 – Ten pin circular connector
J3 – Four pin circular power connector
On the output side, there is one connector:
J4 – WR75 or WR62 waveguide RF output (specify at time of order)
Section 2.2
M
ECHANICAL
I
NSTALLATION
The units are designed to be mounted via 6-32 size screws which must be supplied by the end user.
There are a number of 6-32 UNC threaded holes on each face of the main housing to facilitate mounting
in many different applications and in any orientation; please refer to Appendix A for exact mounting hole
locations. The preferred mounting scheme is to fix the ATOM to the larger assembly using at least four
mounting points on each of two opposite sides of the unit. Other arrangements are possible depending on
the requirements of the application; please contact Norsat technical support for details. Please leave at
least 1 inch of clearance around the fan air intakes.
The unit is entirely watertight and suitable for outdoor operation. All joints are O-ring sealed. The
waveguide port J4 is not internally sealed, so the antenna feed must be sealed with a radome or window,
and all waveguide joints should be O-ring sealed if water-tightness is required.