6
03/15 Rev.G 146527
Rapid Freeze Mode (Freezers Only)
When in rapid freeze mode the compressor will run continuously for 120 minutes and then
return to normal operation and set points.
To Start Rapid Freeze Mode;
• Press ‘Mode/Set’ button.
• Press ‘Up’ or ‘Down’ button until <tb> is displayed.
• Press ‘Mode/Set’ button for two seconds to start rapid freeze.
To Stop Rapid Freeze;
During rapid freeze, press ‘Mode/Set’ button for two seconds. <tb> will flash five times and
then return to normal operation.
Setting Defrost Frequency-
The unit is preset to defrost every 6 hours for freezers ; 12 hours for refrigerators. The
defrost frequency can be set from 4 to 12 hours with a two hour interval. During defrost <dF>
is displayed instead of cabinet temperature.
To set defrost frequency;
• Press ‘Mode/Set’ button.
• Press ‘Up’ or ‘Down’ button until <dt> is displayed.
• Press ‘Mode/Set’ button to see current defrost frequency setting.
• Press ‘Up’ or ‘Down’ button until desired value is displayed.
• Press ‘Mode/Set’ button to set the value.
• Press ‘Up’ or ‘Down’ button until <th> is displayed.
• Press ‘Verify” button to return to display cabinet temperature.
Setting Forced Defrost-
To start a forced defrost;
• Press ‘Mode/Set’ button.
• Press ‘Up’ or ‘Down’ button until <dF> is displayed.
• Press ‘Manual DF’ for 2 seconds to start a forced defrost.
To stop a forced defrost;
During a forced defrost, press ‘Manual DF’ button for 2 seconds to stop a forced defrost.
<dF> will flash five times and then return to normal operation.
Setting Temperature Unit
Setting the temperature unit and temperature control is possible.
(
℉↔℃
)
To select the temperature unit
• Press ‘Mode/Set’ button.
• Press ‘Up’ or ‘Down’ button until <SE> is displayed.
• Press ‘Mode/Set’ button and the current temperature unit is flashing.
• Press ‘Up’ or ‘Down’ button and set the desired temperature unit.
(
℉↔℃
)
• Press ‘Mode/Set’ button to set the value.
• Press ‘Up’ or ‘Down’ button until <th> is displayed.
• Press ‘Verify’ button to return to display cabinet temperature.