The refrigeration system located at the bottom of the unit requires free air access for 

proper operation. Allow a minimum of 180mm (7 inches) between the back of the cabinet 

and the wall. Do not locate the unit next to heat generating equipment or in direct sunlight. 

 

Confirm that the proposed electrical outlet has the correct voltage, frequency and current 

carrying capacity for the requirements of the unit. This information is noted on the data 

plate on the inside left wall of the unit. The unit should be isolated on a circuit. Do not use 

an extension cord to get power to the unit. 

OPERATION 

Once the unit is connected to the proper power supply, the display panel will be lit for two 

(2) seconds followed by a beep, the cabinet temperature will be  displayed and the 

compressor will start to run. The compressor is running whenever ‘COMP’ is lit on the 

display. If the cabinet temperature is higher than +68

(

+15

(refrigerator) or +14

(-5

)

(freezer), the display will read <Hi>. If the cabinet temperature is lower than +14

(

-2

(refrigerator) or -50

(

-40

)

(freezer), the display will read <Lo>. If the unit does not 

start immediately, check the power switch located on the bottom of the top grill. If the 

cabinet temperature is below +14

 (

-10

(freezer) or +50

 (

+10

(refrigerator) when 

the unit is plugged in, there will be a three minute delay before the compressor will start. 

The interior light will come on when a door is opened. The top doors activate the light on 

half-door cabinets only. Note: the light is always on in the Glass Door models. If you want 

to turn off the light, use the light switch on the top grill. 

Whenever a door is opened, the door open light on the display will be lit and the 

evaporator fans will stop. The fans will start three seconds after the door is closed. If a 

door is open for more than 30 seconds, the door open alarm will beep three times. If a door 

is open more than 60 seconds, the alarm beeps five times and if open more than five 

minutes, the alarm will beep continuously.  On half-door cabinets only, the top doors 

activate this feature. 

The electronic control has an alarm function to remind the operator to periodically clean 

the condenser coil. The condenser coil will collect dust and debris during normal 

operation. If left unclean, this will lead to poor performance, high energy consumption and 

possible compressor failure. Warranties do not cover failures related to condenser 

cleaning. At 6-month intervals, the display will blink “CL” and the buzzer will sound to 

remind the operator to clean the condenser coil. After one hour, the buzzer will stop but 

the display will continue to blink “CL”. Refer to the ‘MAINTENANCE’ section of this manual 

to learn how to clean the condenser coil. The electronic control can be reset to normal 

operation by pressing the ‘Mode/Set’ and ‘Verify’ buttons at the same time for five 

seconds. Depending on conditions, the condenser coil may require more frequent 

cleaning. 

When a door is closed on a cabinet that is running, an internal vacuum is created as the 

internal air is cooled and the door can be difficult to open for a  while. These units 

incorporate a pressure relief valve that equalizes the vacuum to allow the door to be 

opened sooner.

Summary of Contents for AdvantEDGE NLF23-S

Page 1: ...r legs to the unit base by screwing them into the threaded fittings that were used to secure the shipping base Use the wrench provided to tighten the casters to the unit The casters with the brakes sh...

Page 2: ...ays on in the Glass Door models If you want to turn off the light use the light switch on the top grill Whenever a door is opened the door open light on the display will be lit and the evaporator fans...

Page 3: ...handle or fa ade parts as they could cause failure Use mild soap and warm water on plastic parts The door gaskets should be cleaned in place with a mild soap solution to extend their life The shelvin...

Page 4: ...4 3 19 Rev G 146527 ELECTRONIC CONTROL 1 ELECTRONIC CONTROLLER DISPLAY PANEL LAYOUT...

Page 5: ...tial is the amount of swing that the cabinet temperature does either side of the temperature set point If the temperature set point is 36 4 and the temperature differential is 8 4 the compressor will...

Page 6: ...e current defrost frequency setting Press Up or Down button until desired value is displayed Press Mode Set button to set the value Press Up or Down button until th is displayed Press Verify button to...

Page 7: ...it does not refrigerate well Temperature set point is too high Correct temperature set point The door is opened too frequently Loading of too much warm or moist product Not enough ventilation Move the...

Page 8: ...3 838mm 33 H 2 127 83 7 2 127 83 7 Swing Doors 1 2 3 1 2 3 Shelves 4 8 12 4 8 12 Compressor 3 5HP 3 4HP 1HP 3 8HP 3 8HP 3 8HP Power Voltage 115V 115V 115V 115V Plug In Installation NEMA 5 15P NEMA 14...

Page 9: ...400 55 2 1 980 78 0 D 835 32 9 H 2 127 83 7 Swing Doors 1 2 3 Shelves 4 8 12 Compressor 3 8HP 3 8HP 3 8HP Power Voltage 115V Plug In Installation NEMA 5 15P Amps 7 5 7 5 7 5 Range of Temperature 0 4 3...

Reviews: