Norlake AdvantEDGE NLF23-S Installation, Operation And Maintenance Instructions Download Page 5

5

                                                     

03/15 Rev.G 146527

 

 

                     

 In converting Temperature Unit (

℉↔℃

), 1

 (1

) deviation can occur.   

ELECTRONIC CONTROL SETTINGS 

Setting Temperature- 

The temperature set point is adjustable from -22

(

-30

)

 to +8

(

-10

)

 for the freezers 

and +25

(+2

)

 to +50

(

+10

)

 for refrigerators. The default set point is -5

(

-20

)

 for 

freezers,  +36

(

+4

)

  for  solid door refrigerators  and    +35

(

+4

)  for glass door 

refrigerators.

 

To set or adjust the cabinet temperature; 

•  Press ‘Mode/Set’ button. 

•  Press ‘Up’ or ‘Down’ button until<St> is displayed. 

•  Press ‘Mode/Set’ button to display current temperature set point. 

•  Press ‘Up’ or ‘Down’ buttons until desired set point is displayed. 

•  Press ‘Mode/Set’ button to set the new value. 

•  Press ‘Up’ or ‘Down’ button until <th> is displayed. 

•  Press ‘Verify’ button to return to display cabinet temperature. 

Setting Temperature Differential- 

The temperature differential is the amount of swing that the cabinet temperature does either 

side of the temperature set point. If the temperature set point is +36

(

+4

)

  and the 

temperature differential is +8

(+

4

)

, the compressor will start when the control shows 

+40

(

+6

)

  and stop when the control shows +32

(

+2

)

.  The default temperature 

differential set point is +8

(+

4

)

 and the range is +4

(+

2

) to +16

(+10

). 

To set the temperature differential; 

•  Press ‘Mode/Set’ button. 

•  Press ‘Up’ or ‘Down’ button until <di> is displayed. 

•  Press ‘Mode/Set’ button to see current temperature differential setting. 

•  Press ‘Up’ or ‘Down’ button until the desired value is displayed. 

•  Press ‘Mode/Set’ button to set the value. 

•  Press ‘Up’ or ‘Down’ button until <th> is displayed. 

•  Press ‘Verify’ button to return to display cabinet temperature. 

Display

 

Description

 

St 

Temperature Setting Mode 

di 

Temperature Differential Setting Mode 

th 

Cabinet Temperature Verification Mode 

dt 

Defrost Frequency Setting Mode 

tb 

Rapid Freeze Mode (Freezers Only) 

dF 

Forced Defrost Mode 

   SE 

Temperature Unit Converter mode (

℉↔℃

 

Summary of Contents for AdvantEDGE NLF23-S

Page 1: ...r legs to the unit base by screwing them into the threaded fittings that were used to secure the shipping base Use the wrench provided to tighten the casters to the unit The casters with the brakes sh...

Page 2: ...ays on in the Glass Door models If you want to turn off the light use the light switch on the top grill Whenever a door is opened the door open light on the display will be lit and the evaporator fans...

Page 3: ...handle or fa ade parts as they could cause failure Use mild soap and warm water on plastic parts The door gaskets should be cleaned in place with a mild soap solution to extend their life The shelvin...

Page 4: ...4 3 19 Rev G 146527 ELECTRONIC CONTROL 1 ELECTRONIC CONTROLLER DISPLAY PANEL LAYOUT...

Page 5: ...tial is the amount of swing that the cabinet temperature does either side of the temperature set point If the temperature set point is 36 4 and the temperature differential is 8 4 the compressor will...

Page 6: ...e current defrost frequency setting Press Up or Down button until desired value is displayed Press Mode Set button to set the value Press Up or Down button until th is displayed Press Verify button to...

Page 7: ...it does not refrigerate well Temperature set point is too high Correct temperature set point The door is opened too frequently Loading of too much warm or moist product Not enough ventilation Move the...