Temperature Setting Options
• Hot water temperatures shown are approximate and may differ from the actual temperature at the
fixture depending on external factors such as the season and length of piping in the system.
• When low temperatures are set (for washing dishes, etc.), if the incoming water temperature is
already quite high, it may be difficult to ensure the outgoing water temperature is as per the setting.
• Please check the temperature displayed before using any hot water.
Be especially careful using hot water after the set temperature has been changed.
• When the hot water temperature is adjusted using thermostat controlled water mixing valves, set the
temperature on the remote controller approximately 20°F (10°C) higher than the required temperature
to ensure the appropriate fixture temperature.
< Display when high temp is set >
(Ex.: 125°F)
(
°F:
)
The temperature settings below are examples. The temperature setting
necessary depends on the usage, the length of piping and the time of year.
*Initial factory setting is 110°F
If fixtures incorporate mixing valves, set the temperature higher than usual.
100 105 110 115 120 125 130 135 140 145 150 160 170 185
Shower, hot water supply, etc.
Washing
dishes, etc.
(
°C (°F):
)
The temperature settings below are examples. The temperature setting
necessary depends on the usage, the length of piping and the time of year.
*Initial factory setting is 40°C (104°F)
Shower, hot water supply, etc.
Washing
dishes, etc.
High temperature
37 38 39 40 41 42 43 44 45 46 47 48
50 55 60 65 70 75 80 85
(99)
(100) (102) (104) (106) (108) (109) (111) (113) (115) (117) (118) (122) (131) (140) (149) (158) (167) (176) (185)
When using
°
F mode:
When using
°
C mode:
*
For applications that occasionally require a higher temperature setting,
locate the remote controller in a convenient location.
* Consult local codes for minimum operating temperatures.
High temperature
Blinks for approximately 10 seconds Lit.
Note : An error code will be displayed when this water heater detects scale build-up
in the heat exchanger.
The error code may be more frequently displayed when the unit is set to a
high temperature. (125°F or higher)
Noritz recommends that water temperature is set as low as possible to prevent
scale build-up in the heat exchanger.