46
Specifications-1
Specifications
Performance
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
NG
LP
45°F (25°C) Rise
Maximum Performance
199,900 btuh
199,900 btuh
Minimum Performance
16,000 btuh
16,000 btuh
7.5 GPM (28.2 L/min.)
0.5-9.8 GPM (2-37 L/min.)
100-150°F (In 5°F intervals),
160, 170, 185°F (14 Options)
120°F (50°C),130°F (54°C),140°F (60°C),185°F (85°C)
(Original is 120°F (50°C))
°F Mode:
°C Mode:
37-48°C (In 1°C intervals),
50-85°C (In 5°C intervals) (20 Options)
Specification
NC199OD (GQ-2857WZ US)
Outdoor Wall Mounted
Direct Ignition
15-150 psi
0.5 GPM (2 L/min.)
23.6" (600mm) x 13.8" (350mm) x 9.4" (240mm)
54 lbs.
0.2 Gallon (1.0L)
3/4"
3/4”
3/4”
120 VAC (60Hz)
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Lightning Protection
Device (ZNR), Overheat Prevention Device, Freezing
Prevention Device, Fan Rotation Detector
Remote Controller, Remote Controller Cord,
Anchoring Screws
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Safety Devices
Casing
Flue Collar
Heat Exchanger
Supply
Consumption
Power Vented
NG : 65W LP : 67W Freeze Prevention 161W