background image

38

39

Install the water heater in a location where it is free from ob-
stacles around the equipment and air is not stagnant in order to
prevent incomplete combustion.

Do not install the water heater near staircases or emergency exit.

Avoid places where fires are common, such as those where
gasoline, benzene and adhesives are handled, or places in
which corrosive gases (ammonia, chlorine, sulfur, ethylene
compounds, acids) are present.

Installation in an improper location may cause failures or
fires.

Install the exhaust vent so that obstacles will not be placed
around the end of the pipe, and exhaust gas will not stagnate.

Do not install the water heater where the exhaust gas blows on
outer walls or material not resistant to heat. Also consider the
surrounding trees and animals.

The heat and moisture from the water heater may cause
discoloration of walls and resinous materials, or corrosion of
aluminum materials.

Avoid installation above gas ranges or stoves.

Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam occur in the installation
location, take measures to prevent the fumes and steam from
entering in the equipment.

Avoid installation in dusty places where sand or dust accumu-
late.
These environments will decrease the performance of the fan,
causing incomplete combustion.

Determine a location of installation where the flow of exhaust
gas is not affected by the outlet of the fan or range hood.

Take care that noise and exhaust gas will not affect neighbors.

Make sure that the location allows installation of the exhaust
vent as specified.

Avoid installation at places where special chemical agents (e.g.,
hair spray or spray detergent) are used.

This may cause incomplete connections or failures.

Locate the appliance in an area where leakage from the unit or connections will not
result in damage to the area adjacent to the appliance or to the lower floors of the
structure. When such locations cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed under the appliance. The pan
must not restrict combustion air flow.

3.

Choosing installation site

Caution

1.

Included accessories

The accessories listed below are contained
in the package. Check these accessories
before installation.

Q'ty

Shape

Part name

Tapping screw

φ

5 x 35

5

Part name

Shape

Q'ty

1

Operation Manual

(with a warranty)/

Installation Manual

1

Remote controller

(see page 48)

Check the gas

Check that the kind of gas indicated on the label, and that used
for the equipment are compatible.

Check the power

The power supply is 120V AC, and 60Hz.
Using a different voltage may cause a
fire or electric shock.

Do not use equipment for purposes other than those specified

Use the gas water heater only for hot water supply or showers,
otherwise it may cause unexpected accidents or failure of the
equipment.

Check Ground water and well water

Check the quality of water thoroughly if it is necessary to use ground water or well water. The
equipment may corrode depending on the quality.

Do not connect to solar water heaters

Do not connect the water heater to solar water heaters. When the water temperature rises in
summer, it becomes uncontrollable. If water is supplied at extremely high temperature, it may
cause burns or failure of the equipment.

* If desired use a water mixing valve to keep the temperature down and present burns.

Replacement

* Check the fixing brackets and exhaust vent yearly to make sure they do not to be replaced. Do

not install it outside or in a bathroom or other occupied room Installation in an improper location
may cause failures or fire.

2.

Before installation

Caution

Manufacturing year and month

X X X X .   X X - X X X X X X

Top of heater

S E R I A L   N U M B E R

Back of heater
Front of heater
Side of heater

Minimum Clearances from Combustible of Non-combustible Construction

Clearance

M a d e   i n   J A P A N

X X X X     X X X X X X

Type of Gas      :  Natural Gas

Max. Water Pressure       : Min. 15psi ~ Max. 150 psi

Electrical Rating               : AC 120 Volts 60 Hz

Manifold Gas Pressure  :  Min. 0.63 ~ Max.  2.3 inches

Inlet Gas Pressure         :  Min.   3.5 ~ Max.  10.5 inches

Recovery Rate  :  241 Gallons/Hour

BTU Input          :  Max. 179,000 ~ Min. 22,000

Model                : N-063

Tel                     :  (949)420-0409

20492 Crescent Bay Dr.Ste.104.Lake Forest CA 92630

NORITZ AMERICA CORPORATION

Automatic Instantaneous Water Heater

REQUIRED CLEARANCES TO COMBUSTIBLES

ANSI Z21.10.3 2000

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliances

Outdoor Install

Indoor Install

36 inches
  1 inch
24 inches
  6 inches

  2 inches

  4 inches

  1 inch

12 inches

Summary of Contents for N-063

Page 1: ...tly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Page 2: ...appliance 2 Do not touch any electrical switch do not use any phone in your building 3 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 4 If you cannot...

Page 3: ...xhaust vent terminal Be sure the gas supplied matches the gas on the rating plate Using an improper gas or electric supply may cause improper operation fire or electric shock Do not allow small childr...

Page 4: ...lean the filter on the water inlet If you don t know where the filter is contact the nearest Noritz agent Keep the area around the unit clean If boxes weeds cobwebs cockroaches etc are allowed to be i...

Page 5: ...d 15 Setting button Before use remove the protective sheet from the remote controller surface Name and Functions of Components Indoor wall mounted power vented model The above illustration shows an ex...

Page 6: ...fixture again 3 Fully open the gas valve Hot water fixture Follow steps 1 through 4 2 Water temperature Ex 104 F Water level The display will flash p 15 Failure indicator When this indicator lights t...

Page 7: ...while hot water is running Flash for 10 sec light up 4 3 Run hot water 2 Adjust temperature Check the indicator lights Hot Cold Water temperature If the remote controller was left set at 167 F the la...

Page 8: ...The setting is remembered Water level will be flashing ex 45 gal The level can be adjusted while the indicator is flashing The temperature will return after ten seconds Set the water level of your tu...

Page 9: ...with insulation or an electric heater If you are still worried that your heater will freeze contact the nearest Noritz agent When the temperature drops the freeze prevention heaters are automatically...

Page 10: ...s method cannot prevent the water supply hot water piping and water supply valve from freezing Be sure to protect them with insulation or an electric heater If you are still worried the unit will free...

Page 11: ...d water supply valves fully open Is the water supply cut off Is the hot water fixture sufficiently open Is the heater frozen Is the gas meter working For LP Is there enough gas in the tank Is the oper...

Page 12: ...y may become unstable when the remote controller is cleaned with a dry cloth Leave it for 30 minutes and it will return to normal Other The Heater stops burning during operation Are the gas and water...

Page 13: ...y service and service will only be performed if the unit is deemed repairable Follow up service Requesting service Minimum period of time for stocking repair parts Noritz will stock repair parts for t...

Page 14: ...Direct Ignition 15 150 PSI 0 75 GPM 20 5 Height x 13 8 Width x 6 7 Depth 38 lbs 0 2 Gallon 3 4 3 4 1 2 120 VAC 60Hz NG XXXW LP XXXW Freeze Prevention 125W Zincified Steel Plate Acryl Coating Stainles...

Page 15: ...CZLA010 1 010 Grommet CXP CXPA026 1 011 Case top cover 2 EDL EDLA005 1 012 Case top cover 1 EDL EDLA004 1 013 Case top packing EDL EDLL001 1 014 Exhaust cylinder packing EDL EDLL002 1 031 Cross recess...

Page 16: ...ifold seal packing side DTJ Manifold seal packing bottom DTJ Gas mech S16D EDN SET V O ring P18 O ring P28 Gas fitting 15A SET EDN Conduit R10 EDN Cross recessed round head collar N tapping screw 4X8...

Page 17: ...ET V Heater fastener CRP Freeze preventive heater 3 BGD Quick fastener for 13 22 Quick fastener for 16 25 Quick fastener 16A O ring P12 5 O ring P16C O ring P16 F point thermostat BVU Water level sens...

Page 18: ...vice mounting SET DTJ Conduit 92 100V EAU Drip proof cover DTJ Cross recessed bind machine screw M3 5X6 700 701 705 706 707 709 710 711 712 708 713 731 1 1 1 1 1 1 1 1 1 1 1 Part Nos Part Names Order...

Page 19: ...llation Guide upon completion of the installation work Please put your information on the warranty card in the operation manual and give it to the customer when installation is completed Requests to i...

Page 20: ...elow are contained in the package Check these accessories before installation Q ty Shape Part name Tapping screw 5 x 35 5 Part name Shape Q ty 1 Operation Manual with a warranty Installation Manual 1...

Page 21: ...convenient to leave 8 inches or more distance at both sides for inspection Leave 24 inches or more space in front so as to facilitate inspection and repair of the equipment Leave sufficient distance w...

Page 22: ...oden screw 1 Use only listed category III vent pipe with this water heater 2 Follow the vent pipe manufactures installation in structions 3 Apply commercial silicon seal at the joints joint of exhaust...

Page 23: ...ystem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa The appliance and its gas conn...

Page 24: ...r a local plumbing inspector on how to control this situation A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying with either The Standar...

Page 25: ...in the water heater Tie the redundant cord outside the water heater Do not put the extra length inside the equipment Keep the remote controller cord length below 100 meters Use a Y type terminal with...

Page 26: ...tion lamp turns on Caution Lighting Instructions This water heater does not have a pilot It is equipped with an ignition device that automatically lights the burner Do not try to light the burner by h...

Page 27: ...pen Vcc Vcc LS SM BL Y W O G BK V R V BK G O W Y R BL THERMAL FUSE FLAME ROD WATER FLOW SENSOR WATER INLET THERMISTOR WATER OUTLET THERMISTOR FAN MOTOR BL R BL Y BL BL W W BL BL BL BL BL BL Y R BL W Y...

Page 28: ...entive packing Stay pipe Cap nut Connecting electric cord Wind the redundant cord here Connecting electric cord Outdoor cover Cap nut Take off the released paper For in wall wiring 1 Put the remote co...

Page 29: ...n 0 63 Max 2 3 inches Inlet Gas Pressure Min 3 5 Max 10 5 inches Recovery Rate 241 Gallons Hour BTU Input Max 179 000 Min 22 000 Model N 063 Tel 949 420 0409 20492 Crescent Bay Dr Ste 104 Lake Forest...

Page 30: ...58...