background image

22

23

Remote controller

The water temperature changes
after a power failure or when the
power is disconnected.

The operation light does
not come on

Has there been a power failure?

Is the power connected properly?

The time on the controller may need to be reset after a
power failure or after the power has been disconnected.
Also, the hot water temperature indicator, and tub level
alarm may have been reset.

Amount of hot water

The pressure at a certain
fixture is not constant.

When hot water is demanded at other fixtures, the
amount available may be reduced.

Pressure fluctuations and other plumbing conditions can
cause the temperature and pressure at a fixture to be
unstable, but it should stabilize after a short time.

To keep the temperature stable, the heater limits the
amount of water that can flow through it to a small
amount initially, but the amount increases over time.

The display (LCD) is unstable.

The liquid crystal display may become unstable when
the remote controller is cleaned with a dry cloth (Leave it
for 30 minutes and it will return to normal).

Other

The Heater stops burning during
operation.

Are the gas and water supply valves fully open?

Is the water supply cut off?

Is the hot water fixture sufficiently open?

Is the gas meter working?

(For LP) Is there enough gas in the tank?

This is normal on cold days.

White smoke comes out of the
exhaust vent on a cold day.

The hot water becomes turbid.

This is harmless.  Small bubbles appear as the air in the
water is heated and depressurized rapidly to
atmospheric pressure.  It is similar to the bubbles in beer
or carbonated beverages.

Water leaks from the drain plugs on
the outlet.

When the main unit is highly pressurized, water will leak
from the drain plugs as a safety so that the unit is not
damaged by the high pressure.

These plugs are pressure relief valves.  If water is
leaking out of them, excessive pressure is being
supplied to the unit.

Sound

The fan can be heard after
operation is stopped.

The fan runs for a while to accelerate ignition after the
operation button is turned on.

Troubleshooting-2

Summary of Contents for N-063

Page 1: ...tly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WH...

Page 2: ...appliance 2 Do not touch any electrical switch do not use any phone in your building 3 Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions 4 If you cannot...

Page 3: ...xhaust vent terminal Be sure the gas supplied matches the gas on the rating plate Using an improper gas or electric supply may cause improper operation fire or electric shock Do not allow small childr...

Page 4: ...lean the filter on the water inlet If you don t know where the filter is contact the nearest Noritz agent Keep the area around the unit clean If boxes weeds cobwebs cockroaches etc are allowed to be i...

Page 5: ...d 15 Setting button Before use remove the protective sheet from the remote controller surface Name and Functions of Components Indoor wall mounted power vented model The above illustration shows an ex...

Page 6: ...fixture again 3 Fully open the gas valve Hot water fixture Follow steps 1 through 4 2 Water temperature Ex 104 F Water level The display will flash p 15 Failure indicator When this indicator lights t...

Page 7: ...while hot water is running Flash for 10 sec light up 4 3 Run hot water 2 Adjust temperature Check the indicator lights Hot Cold Water temperature If the remote controller was left set at 167 F the la...

Page 8: ...The setting is remembered Water level will be flashing ex 45 gal The level can be adjusted while the indicator is flashing The temperature will return after ten seconds Set the water level of your tu...

Page 9: ...with insulation or an electric heater If you are still worried that your heater will freeze contact the nearest Noritz agent When the temperature drops the freeze prevention heaters are automatically...

Page 10: ...s method cannot prevent the water supply hot water piping and water supply valve from freezing Be sure to protect them with insulation or an electric heater If you are still worried the unit will free...

Page 11: ...d water supply valves fully open Is the water supply cut off Is the hot water fixture sufficiently open Is the heater frozen Is the gas meter working For LP Is there enough gas in the tank Is the oper...

Page 12: ...y may become unstable when the remote controller is cleaned with a dry cloth Leave it for 30 minutes and it will return to normal Other The Heater stops burning during operation Are the gas and water...

Page 13: ...y service and service will only be performed if the unit is deemed repairable Follow up service Requesting service Minimum period of time for stocking repair parts Noritz will stock repair parts for t...

Page 14: ...Direct Ignition 15 150 PSI 0 75 GPM 20 5 Height x 13 8 Width x 6 7 Depth 38 lbs 0 2 Gallon 3 4 3 4 1 2 120 VAC 60Hz NG XXXW LP XXXW Freeze Prevention 125W Zincified Steel Plate Acryl Coating Stainles...

Page 15: ...CZLA010 1 010 Grommet CXP CXPA026 1 011 Case top cover 2 EDL EDLA005 1 012 Case top cover 1 EDL EDLA004 1 013 Case top packing EDL EDLL001 1 014 Exhaust cylinder packing EDL EDLL002 1 031 Cross recess...

Page 16: ...ifold seal packing side DTJ Manifold seal packing bottom DTJ Gas mech S16D EDN SET V O ring P18 O ring P28 Gas fitting 15A SET EDN Conduit R10 EDN Cross recessed round head collar N tapping screw 4X8...

Page 17: ...ET V Heater fastener CRP Freeze preventive heater 3 BGD Quick fastener for 13 22 Quick fastener for 16 25 Quick fastener 16A O ring P12 5 O ring P16C O ring P16 F point thermostat BVU Water level sens...

Page 18: ...vice mounting SET DTJ Conduit 92 100V EAU Drip proof cover DTJ Cross recessed bind machine screw M3 5X6 700 701 705 706 707 709 710 711 712 708 713 731 1 1 1 1 1 1 1 1 1 1 1 Part Nos Part Names Order...

Page 19: ...llation Guide upon completion of the installation work Please put your information on the warranty card in the operation manual and give it to the customer when installation is completed Requests to i...

Page 20: ...elow are contained in the package Check these accessories before installation Q ty Shape Part name Tapping screw 5 x 35 5 Part name Shape Q ty 1 Operation Manual with a warranty Installation Manual 1...

Page 21: ...convenient to leave 8 inches or more distance at both sides for inspection Leave 24 inches or more space in front so as to facilitate inspection and repair of the equipment Leave sufficient distance w...

Page 22: ...oden screw 1 Use only listed category III vent pipe with this water heater 2 Follow the vent pipe manufactures installation in structions 3 Apply commercial silicon seal at the joints joint of exhaust...

Page 23: ...ystem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa The appliance and its gas conn...

Page 24: ...r a local plumbing inspector on how to control this situation A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying with either The Standar...

Page 25: ...in the water heater Tie the redundant cord outside the water heater Do not put the extra length inside the equipment Keep the remote controller cord length below 100 meters Use a Y type terminal with...

Page 26: ...tion lamp turns on Caution Lighting Instructions This water heater does not have a pilot It is equipped with an ignition device that automatically lights the burner Do not try to light the burner by h...

Page 27: ...pen Vcc Vcc LS SM BL Y W O G BK V R V BK G O W Y R BL THERMAL FUSE FLAME ROD WATER FLOW SENSOR WATER INLET THERMISTOR WATER OUTLET THERMISTOR FAN MOTOR BL R BL Y BL BL W W BL BL BL BL BL BL Y R BL W Y...

Page 28: ...entive packing Stay pipe Cap nut Connecting electric cord Wind the redundant cord here Connecting electric cord Outdoor cover Cap nut Take off the released paper For in wall wiring 1 Put the remote co...

Page 29: ...n 0 63 Max 2 3 inches Inlet Gas Pressure Min 3 5 Max 10 5 inches Recovery Rate 241 Gallons Hour BTU Input Max 179 000 Min 22 000 Model N 063 Tel 949 420 0409 20492 Crescent Bay Dr Ste 104 Lake Forest...

Page 30: ...58...