17

10.

 Water Piping

This appliance is suitable for combination potable water and space heating applications. It cannot be used for space 

heating applications only. Do not use this appliance if any part has been underwater.  Immediately call a qualified 

service technician to inspect the appliance and replace any part of the control system and gas control which has 

been under water.

If the water heater is installed in a closed water supply system, such as one having a backflow preventer in the 

cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or a local 

plumbing inspector on how to control this situation.
A pressure relief valve must be installed near the hot water outlet that is rated in accordance with and complying 

with  either The  Standard  for  Relief  Valves  and Automatic  Shutoff  Devices  for  Hot  Water  Supply  Systems, ANSI 

Z21.22, or The ANSI/ASME Boiler and Pressure Vessel Code, Section IV ( Heating Boilers ). This pressure relief 

valve must be capable of an hourly Btu rated temperature steam discharge of 199,900 Btuh. Multiple valves may be 

used. The pressure relief capacity must not exceed 150 psig. No valve shall be placed between the relief valve and 

the water heater. The relief valve must be installed such that the discharge will be conducted to a suitable place for 

disposal when relief occurs. No reducing coupling or other restriction may be installed in the discharge line. The 

discharge line must be installed to allow complete drainage of both the valve and the line. If this unit is installed with 

a separate storage vessel, the separate vessel must have its own temperature and pressure relief valve. This valve 

must also comply with The Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply 

Systems, ANSI Z21.22. (in the U.S. only). A temperature relief valve is not required, but if one is used, do not install 

the valve with the probe directly in the flow of water. This may cause unwarranted discharge of the valve.

Piping and components connected to the water heater shall be suitable for use with potable water.

Toxic chemicals, such as those used for boiler treatment, shall not be introduced into the potable water.

A  water  heater  used  to  supply  potable  water  may  not  be  connected  to  any  heating  system  or  components 

previously used with a nonpotable water heating appliance.

When water is required in one part of the system at a higher temperature than in the rest of the system, means 

such as a mixing valve shall be installed to temper the water to reduce the scald hazard.

Installation and service must be performed by a qualified plumber.  In the 

Commonwealth of Massachusetts, this product must be installed by a licensed 

plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel 

Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes.

•  Flush water through the pipe to clean out metal powder, sand and dirt before connecting it.

•  Perform the following insulation measures for prevention of freezing. 

-  Take appropriate heat insulation measures (e.g., wrapping with heat 

insulation materials, using electric heaters) according to the climate 

of the region to prevent the pipe from freezing.

-  Make sure that there are no water leaks from the cold and hot water 

supply pipes, then insulate the pipes completely. 

-  Be sure to also completely insulate the water supply valve and the 

cold and hot water connections on the water heater (refer to the fig

-

ure on the right).  

-  Do not cover the water drain plug with insulation so that water in the 

pipe can be drained. (Refer to the figure in the right.)  

• 

Use a union coupling or flexible pipe for connecting the pipes to reduce the force applied to the piping.

•  Do not use piping with a diameter smaller than the coupling.

•  When feed water pressure is too high, insert a depressurizing valve, or take water hammer prevention measure.

•  Avoid using joints as much as possible to keep the piping simple.

•  Avoid piping in which an air holdup can occur.

•  If installing the unit on a roof:

•  About lower-level hot water supply

  If the unit is installed on a roof to supply water to the levels below, make sure that the water pressure supplied 

to the unit does not drop below 29 psi. It may be necessary to install a pump system to ensure that the water 

pressure is maintained at this level.

  Check the pressure before putting the unit into operation.

  Failure to supply the proper pressure to the unit may result in noisy operation, shorter lifetime of the unit, and 

may cause the unit to shut down frequently.

Completely insulate 

the water inlet and 

outlet fittings.

Insulate the water 

supply valve completely.

Do not cover the water 

drain plug with insulation

so that water in the pipe 

can be drained.

Pipe 

Size

Length  (including fittings)

10'

20'

30'

40'

50'

60'

70'

80'

90'

100'

125'

150'

200'

(3m)

(6m)

(9m) (12m) (15m) (18m) (21m) (24m) (27m) (30m) (38m) (45m) (60m)

1/2"

275

189

152

129

114

103

96

89

83

78

69

63

55

3/4"

567

393

315

267

237

217

196

185

173

162

146

132

112

1"

1,071

732

590

504

448

409

378

346

322

307

275

252

213

1 1/4" 2,205 1,496 1,212

1039

913

834

771

724

677

630

567

511

440

1 1/2" 3,307 2,299 1,858 1,559 1,417 1,275 1,181 1,086 1,023

976

866

787

675

2"

6,221 4,331 3,465 2,992 2,646 2,394 2,205 2,047 1,921 1,811 1,606 1,496 1,260

Summary of Contents for GQ-2857WX-F US

Page 1: ...instructed in this manual are not covered by the warranty Check that the installation was done properly in accordance with this Installation Manual upon completion After completing installation please...

Page 2: ...the units but may be necessary for installation Quick Connect Cord Q ty Shape Part Part Shape Q ty 1 1 Remote Controller Cord 26ft 8m 1 Isolation Valves includes pressure relief valve Pipe Cover PC 3S...

Page 3: ...tor Cord Connector 3 Quick Connect Multi System Installation The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord Typical Plumbing The Qui...

Page 4: ...line is sized for 199 900 Btuh for this unit Check the Power The power supply required is 120VAC at 60Hz May result in fire or electric shock Use Extreme Caution if Using With a Solar Pre Heater Usin...

Page 5: ...which corrosive gases ammonia chlorine sulfur ethylene compounds acids are present Using the incorrect voltage may result in fire or cracking Avoid installation in places where dust or debris will acc...

Page 6: ...r heater must be braced anchored or strapped to avoid moving during an earthquake Contact local utilities for code requirements in your area or call 1 866 766 7489 and request instructions Be sure to...

Page 7: ...0mm or more on either side of the unit to facilitate inspection If possible leave 24 600mm or more in front of the unit to facilitate maintenance and service if necessary If possible leave 3 75mm or m...

Page 8: ...opane Installation Code 2 In accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code A vent shall not terminate directly above a sidewalk or paved driveway that is located between two s...

Page 9: ...ion Do not drop or apply unnecessary force to the device when installing Internal parts may be damaged and may become highly dangerous Install the unit on a vertical wall and ensure that it is level L...

Page 10: ...instructions of the vent manufacturer Appliance Adapters When using a vent system other than N Vent an appliance adapter will be required to properly connect the vent to this appliance Consult the man...

Page 11: ...on is recommended to prevent debris from falling into the water heater Install a condensation drain in the horizontal section of the venting For installations in tight spaces where there is not enough...

Page 12: ...m clearance in front of the unit to the door If combustion air will be provided through a duct size the duct to provide 60 cubic feet of fresh air per minute Supply combustion air to the units as per...

Page 13: ...he installer The installer must be professionally trained to do such work and must always follow all local and national codes and regulations Gas line sizing calculations must be performed for every i...

Page 14: ...length from the meter or regulator so that the following supply pressures are available even at maximum demand WARNING Natural Gas Supply Pressure Min 4 WC Max 10 5 WC LP Gas Supply Pressure Min 8 WC...

Page 15: ...45 13 5m Use 50 15m 175 000 Btuh requires 1 Outlet E 25 7 5m Use 30 9m 199 900 Btuh requires 3 4 Section 4 45 13 5m Use 50 15m 355 000 Btuh requires 1 1 4 Natural Gas Meter Noritz Tankless Gas Water...

Page 16: ...ce to verify all appliances are receiving a minimum of 5 WC for NG or 8 WC for LP If all appliances are not receiving the minimum inlet pressure the gas piping system may need to be changed CAUTION Pi...

Page 17: ...t be connected to any heating system or components previously used with a nonpotable water heating appliance When water is required in one part of the system at a higher temperature than in the rest o...

Page 18: ...nd decreasing the durability of the heat exchanger Freeze Prevention Freezing is prevented within the device automatically unless the outside temperature without wind is below 30 F 35 C The room tempe...

Page 19: ...ration is an example Please check with the actual water heater about the position of piping and form If this water heater will be installed in an application where the supply water is hard the water m...

Page 20: ...n the other to the circulating pump 4 Connect the drain hose H2 to the circulating pump 5 Connect the drain hose H3 to the drain valve V4 6 Pour 1 gallon of and gallon water into the bucket Noritz rec...

Page 21: ...the flushing solution through the water heater for 1 hour at a rate of 1 5 gallons per minute or more 5 The code C60 is displayed on the Remote Controller when the water heater detects the flow of th...

Page 22: ...pply valves and water out let valves 9 Check for correct operation of the water heaters is displayed when the Main Water Heater s bule connector is connected is displayed when the Sub Water Heater s b...

Page 23: ...ve with unions and a pressure relief valve Notes 1 Noritz recommends the use of an Isolation Kit with the installation These kits include an integrated shut off and service valve with unions and a pre...

Page 24: ...icing Field wiring to be performed at time of appliance installation The electrical supply required by the water heater is 120VAC at 60 Hz The power consumption may be up to 262W or higher if using op...

Page 25: ...On Off Button on the remote controller To keep the water heater off let the unit sit for 30 sec to return to the original display This unit can be programmed so that it will default to one of three te...

Page 26: ...the end of the remote controller cord to the terminal block 5 Replace the terminal block cover and install the screw previously removed in step 3 6 Reconnect electrical power to the water heater Exte...

Page 27: ...m a wall circuit to the pump 5 Replace the front cover Pump Wiring This feature is not available when using the Quick Connect Multi System feature Relay connection with larger pumps 85 W 1 Locate and...

Page 28: ...mp Ground wire Connector Use one of the vacant holes Connector Connecting Quick Connect Cord 2 Caution For Quick Connect Multi System Installation use part QC 2 only sold separately Quick Connect Cord...

Page 29: ...a proper blue color and consistency If the flame does not appear normal the burner may need to be cleaned If the burner needs to be cleaned it must be performed by a qualified service technician Do no...

Page 30: ...ower to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop a...

Page 31: ...m 4 100mm 13 1 334mm 1 1 28mm 3 7 95mm 0 4 10mm 0 4 10mm 2 4 60mm 2 0 50mm 24 5 622mm 22 3 567mm 23 6 600mm 2 8 70mm 1 6 41mm 4 0 5 13mm FLUE COLLAR AIR INLET WIRING THROUGHWAY WATER DRAIN VALVE WATER...

Page 32: ...s on the Installation Location The remote should be installed in an easily accessible location Avoid installing in a place where water or steam can come into contact with the controller Avoid location...

Page 33: ...ord Phillips Roundhead Wood Screw Wall Anchor 3 Remove the cover of the remote control mark the location of the screw holes and drill holes for the wall anchors 4 Insert the wall anchors screw the rem...

Page 34: ...r In order to use this product safely read this installation manual carefully and follow the installation instructions Potential dangers from accidents during installation and use are described below...

Page 35: ...t The value in indicates the quantity Remote Controller Mounting bracket Raised countersunk head wood screw Wall anchor Raised countersunk head screw For junction box installation Machine screw When a...

Page 36: ...f the remote controller and the frame pull the entire decorative frame forward while pressing the sections indicated where the fingers are in the figure below If it does not come off insert a flat hea...

Page 37: ...higher temperature settings through the remote controller follow the below steps When setting the maximum temperature to 125 140 F 55 60 C 1 Turn the water heater off by pressing the Power On Off But...

Page 38: ...e controller 2 Disconnect then reconnect electrical power to the water heater 3 Press the MENU Button inside the cover select Initial settings using the Buttons 4 Press the ENTER button the Initial se...

Reviews: