• Avoid installation above gas ranges or stoves.
• Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam are present in the installation
location, take measures to prevent the fumes and steam from
entering in the equipment.
• Install in a location where the exhaust gas flow will not be
affected by fans or range hoods.
• Take care that noise and exhaust gas will not affect neighbors.
Avoid installation on common walls as the unit will make some
operational noises while it is running.
• Make sure that the location allows installation of the exhaust
vent as specified.
• Avoid installation where the exhaust vent terminal will be
exposed to excessive winds.
• Before installing, make sure that the exhaust flue termination
will have the proper clearances according to the National Fuel
Gas Code (ANSI Z223.1-latest edition) or the Natural Gas and
Propane Installation Code (CSA B149.1).
State of California: The water heater must be braced, anchored or strapped to avoid moving during
an earthquake. Contact local utilities for code requirements in your area or call: 1-8-7-7489 and
request instructions.
Be sure to do
Prohibited
Prohibited
CAUTION
The Commonwealth of Massachusetts: The water heater can be used for hot water only and not in a
combination of domestic and space heating.
For Venting Manufacturers Requirements, see websites or phone numbers listed below:
Noritz N-Vent
www.noritz.com
• Install the water heater in a location where it is free from obstacles and
stagnant air.
• Consult with the customer concerning the location of installation.
• Do not install the water heater near staircases or emergency exits.
• Do not install the water heater where the exhaust will blow on outer walls
or material not resistant to heat. Also consider the surrounding trees and
animals.
The heat and moisture from the water heater may cause discoloration of
walls and resinous materials, or corrosion of aluminum materials.
• Do not locate the vent termination directed towards a window or any other
structure which has glass or wired glass facing the termination.