Troubleshooting-1

 

                            Contact Noritz America if:

•  Any other error code appears.

•  An error code is indicated again after the above actions were followed.

•  There are any other questions.

Check for an Error Code on the Display Window or Optional Remote Controller

If there is a problem with the unit, a numerical error code will flash on the display window or 

optional remote controller.

If this occurs, take appropriate measures as listed below.

When an error code appears, the display and the 

operation light will flash together.

Flashing

Optional Remote Controller

Display Window

Remote Controller

Cause

Action 

Error Code Error Code

Ignition error.

Check whether the gas valve is open. Unplug 

the unit from power or press the power button 

on the optional remote controller to turn the 

unit off, open a  hot water fixture, and turn the 

unit back on. If the flashing number doesn’t 

return, the problem is solved.

Clogging of condensate trap 

or drain pipe.

Check to see if the condensate drain pipe is 

clogged or frozen. (

 

p.8)

Contact the installer or Noritz America 

Technical Support for assistance.

Abnormal combustion.

[When supplying combustion 

air from the indoors]

The air supply vent may be 

clogged.

Clean the air supply vent. (

 

p.22)

If the display continues, contact the nearest 

Noritz agent.

Abnormal combustion,

low gas supply pressure.

Have a professional check the gas supply pressure.

Contact the nearest Noritz agent.

Abnormal combustion.

Contact the nearest Noritz agent.

The outlet temperature is 

colder than set temperature.

Contact the nearest Noritz agent.

The indication on the display window shown is not an error of unit.

If you try to supply a low flow of water when the inlet water temperature 

is high, hot water is not supplied sometimes (combustion is automatically 

stopped and the temperature of hot water does not become hot).

Display Window

Summary of Contents for eco TOUGH NRC661

Page 1: ...in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death WARNING Thank you for purchasing this Noritz Tankless Gas Water Heater Before us...

Page 2: ...situation which if not avoided may result in property damage CAUTION Be sure to do Ground Electric Shock DANGER Icons warning of risk level Important Safety Information 1 This is the safety alert symb...

Page 3: ...ry to repair it Call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this water heater if any part has been under water lmmediately call a quali...

Page 4: ...re may be blown by the wind causing malfunction or fire as a result Prohibited Outdoor Leave the proper clearance between the water heater and nearby objects trees timber boxes with flammable material...

Page 5: ...injury or death The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checke...

Page 6: ...n water within the device and pipes even in warm environments Be sure to read below for appropriate measures Repairs for damage caused by freezing are not covered by the warranty Take necessary measur...

Page 7: ...e remote controller Using the Water Heater 12 How to Use Using the optional remote controller Remote Controller 13 Setting and Using the Water Heater 14 Flow Meter Alarm 16 Muting the Remote Controlle...

Page 8: ...water heater a condensing type captures heat from the exhaust gas and uses it to preheat the incoming cold water as it passes through the secondary heat exchanger as illustrated below The condensing t...

Page 9: ...ver Water Supply Valve Unit Components Intake Pipe Flue Collar Drain Pipe Discharges the condensate NRC661 OD Outdoor Wall Mounted Power Vented Model Exhaust Vent Pressure Relief Valve Water Drain Val...

Page 10: ...on set temperature s is displayed for one minute When hot water flows If there is a problem with the unit a numerical error code will flash p 25 When unit is initially plugged into power set temperat...

Page 11: ...and then close the fixture again 3 Open the gas supply valve Hot water fixture 2 Plug into power CLOSED 4 OPEN Do not touch with wet hands Ex NRC661 DV Please check the following when you use the wate...

Page 12: ...r death from scalding Children disabled and elderly are at the highest risk of being scalded Feel water temperature before bathing or showering Temperature limiting valves are available ask profession...

Page 13: ...ton p 16 Error Code When this indicator is lit the hot water temperature can be set p 14 If you want to change the temperature of supplied hot water frequently or you want to set the amount of hot wat...

Page 14: ...ations the recommended setting temperature is 120 F 50 C 122 F or less Consult local codes for minimum operating temperatures 100 105 110 115 120 125 130 135 140 Shower hot water supply etc Washing di...

Page 15: ...Feel water temperature before bathing or showering Temperature limiting valves are available ask professional person When setting the unit to 125 F 55 C 131 F or higher the temperature display will fl...

Page 16: ...cator lights Water temperature Press the flow meter alarm set button the setting will flash on the display and adjust with the setting buttons Increase Decrease Choose the flow meter alarm setting fro...

Page 17: ...low If there was water in the tub before the fill began the temperature in the tub after it is full may be different from the temperature setting Initial factory setting 110 F or 40 C 104 F Water Temp...

Page 18: ...sound when muted Hold the Power On Off Button for five seconds Sound Muted No sound after 5 sec Tone sounds after 5 sec Turn off the Power On Off Button Press and hold the flow meter alarm set button...

Page 19: ...water through the unit when it is OFF p 6 but in this case freeze prevention is more important Remember to set mixing valves and fixtures to their original levels before using the unit again to preve...

Page 20: ...he power supply after 2 minutes or more pass from operation of 2 Using the remote controller Turn off the power supply 4 Close the water supply valve 5 Fully open all hot water fixtures 6 Turn the dra...

Page 21: ...from the drain pipe within 15 minutes of use However depending on the season and or installation site conditions it may take longer If water does not appear at the end of the drain line a qualified s...

Page 22: ...or scalding turn off the power button or power supply and wait until the unit cools before performing maintenance CAUTION Be sure to do Check For laundry newspaper timber oil spray cans and other com...

Page 23: ...ures 3 With a bucket ready remove the inlet and outlet drain plugs about 0 2 gallon 0 9L will drain out 4 Take the water drain valve with water filter out of the inlet See illustration to right 5 Clea...

Page 24: ...er as a result of poor water quality is not covered by the Limited Warranty To ensure full warranty coverage treat or condition water that exceeds the target levels provided in this table Source EPA N...

Page 25: ...rn the unit back on If the flashing number doesn t return the problem is solved Clogging of condensate trap or drain pipe Check to see if the condensate drain pipe is clogged or frozen p 8 Contact the...

Page 26: ...a stoves by used Is the water drain valve filter clogged p 23 Is the power button optional remote controller turned on No water is available when a fixture is opened Is the water supply cut off Check...

Page 27: ...ter temperature is too high The unit will not fire because it will over heat the outlet water Using the optional remote controller Fluctuations in hot water temperatures Set water temperature at 115 F...

Page 28: ...amount of hot water available Scale can be removed from the water heater by flushing the unit periodically To prevent scale from forming in the water heater a water softener or scale inhibitor is rec...

Page 29: ...water discharge from the drain pipe Condensation forms inside the unit during operation and is discharged from the drain pipe Sounds Problems What to do Display Window The fan can be heard after oper...

Page 30: ...est for service may be rejected if the water heater is installed in a location where working on the unit may be dangerous Contact a plumber We will need to know The Model check the rating plate See p...

Page 31: ...be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction The information in the inst...

Page 32: ...ations Performance Item Model Name Type Ignition Operating Pressure Minimum Flow Rate Dimensions Height x Width x Depth Weight Water Holding Capacity Accessories Installation Air Supply Exhaust Connec...

Reviews: