VS18/VS26
MAINTENANCE & INSTRUCTION BOOKLET
•
Any fitting position of the valve island is permissible but valves with indicating lights up is
preferred.
•
To avoid damaging the product, please make sure that the maximum torque values are not
exceeded (see section
•
Avoid short-circuits and breaks by not deviating from the standard use of connector cables
and cords.
•
Order spare parts with the part number indicated on the product labels. (See section
and/or data sheets 5.4.159 (VS18) resp. 5.4.160 (VS26)).
•
Do not load the system by bending or torsion.
•
Important: Power must be removed from the system while assembling and disassembling
electrical connectors, plugs and cables, valves, sandwich plates and blanking plates.
•
Install and use only complete configured and connected valve islands.
•
VS18/VS26 Fieldbus valve islands contain electronic devices, which could be damaged
through electrostatic discharge. Therefore electrostatic precautions must be taken.
Specifically, the person assembling or configuring the valve island must be connected to an
earth ground.
•
Please refer to section
for information on power supply and earth ground connection of
Multipole and Fieldbus valve islands.
•
Use this booklet or the instruction sheets packed with the product for assembling and
installation.