UKLEETC002023293
010
VP50 IO-Link
02/21
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document. (2019 - 9261a) © 2019 Norgren GmbH
4.2 Diagnostic
Indicators
LED Status
Description
Green Off
No power
Green Solid
Power OK
Green Flashing
IO-Link Communications established
Red On
* Refer to error table below
Error Event Code
Detailed Device Status
Fault Description
Recommendation
0x5000
Device hardware fault
Internal hardware fault
Cycle power to unit. If error remains
contact Technical Support
0x183A
IOLink PHY chip fault
IO-Link hardware fault
Check power supply voltage is within
specification
0x6320
Parameter error
Demanded pressure outside of
unit specification
Check demanded pressure is
achievable.