5
ASSEMBLY AND OPERATION
This fixture is designed to work on square edged doors either 1-3/4” or 2-1/4” thick.
TOOLS REQUIRED FOR SET-UP
• Set of SAE hex keys (1/8”, 5/32” & 3/16”)
BASIC ASSEMBY
The lock installation instructions should be read carefully to determine if the lock
location should be referenced from the top or the bottom of the door. Traditionally, in
prehanging the lock is located from the top of the door, however many multipoint locks
are referenced from the bottom of the door. All three Base Units are symmetrical, so they
will operate from either the top or bottom reference. The Top and Bottom Base Units are
identical, so they will operate in either case.
The following setup is for reference from the bottom of the door.
Reference figures 1, 2 & 3
Note: This will position the lock so that the bottom of the faceplate will be flush with the
bottom of the door. The lock location from the top of the door will vary depending upon
the exact height of the door.
BASE UNITS
– The Index Bar should be oriented such that the scale can be read
from the side on which the Base Units are installed. Install the Top, Center and
Bottom Base Units by aligning the 80/20 bearing with clamp (part number 4 in
figures 5 & 6) on the Index Bar.
END STOP
– The End Stop should be installed to align with the “0” position on
scale. Use a 5
/
32” hex key to install screws.