INSTALLATION/PERFORMANCE CHECK LIST
O’Fallon, MO
¢708880<¤
708880A
*
* Gama Listing is applicable only to units having an input rate 225,000 Btu/hr or greater
INSTALLER NAME:
CITY _______________________
STATE ________________
GAS SYSTEM:
Gas Type: (circle one)
Natural
Gas
Propane
Gas pipe connections leak-tested?
YES
NO
Gas Line Pressure: _____________________________(in - W.C.)
Is there adequate fresh air
supply for combustion and
ventilation?
YES
NO
Installation Altitude: ______________________________ (FT.)
Deration Percentage: ______________________________ (%)
Furnace Input: _________________________________(Btuh)
Supply Air Temperature: __________________________ (° F)
Return Air Temperature: __________________________ (° F)
Temperature Rise: _______________________________ (° F)
During Furnace Operation:
Low fi re manifold pressure: _______________________(in - W.C.)
High fi re manifold pressure: _______________________(in - W.C.)
REFRIGERATION SYSTEM:
Was unit given 24 hr warm up period
for crankcase heaters?
YES
NO
Stage-1 Liquid Pressure (high side) ________________________
Stage-1 Liquid Temperature ______________________________
Stage-1 Suction Pressure (low side) ________________________
Stage-2 Liquid Pressure (high side) ________________________
Stage-2 Liquid Temperature ______________________________
Stage-2 Suction Pressure (low side) ________________________
Has the owner’s information been
reviewed with the customer?
YES
NO
Has the Literature Package been left
with the unit?
YES
NO
INSTALLATION ADDRESS:
CITY ________________________
STATE ________________
UNIT MODEL # ________________________________________
UNIT SERIAL # ________________________________________
Unit Installed Minimum clearances per
Figure 6 (page 9)?
YES
NO
ELECTRICAL SYSTEM:
Electrical connections tight?
YES
NO
Line voltage polarity correct?
YES
NO
Rated Voltage: ___________________________________ VOLTS
L1-L2 Volts: _____________________________________ VOLTS
L1-L3 Volts: _____________________________________ VOLTS
L2-L3 Volts: _____________________________________ VOLTS
Avg. Volts: ______________________________________ VOLTS
Max. deviation of voltage
from avg. volts: ___________________________________ VOLTS
% Volt imbalance: ________________________________ VOLTS
Blower Motor HP: _________________________________ VOLTS
Has the thermostat been calibrated?
YES
NO
Is the thermostat level?
YES
NO
Is the heat anticipator setting
correct?
YES
NO
VENTING SYSTEM:
Is the vent hood installed?
YES
NO
Is vent hood free from restrictions
YES
NO
Filter(s) secured in place?
YES
NO
Filter(s) clean?
YES
NO