Auxiliary Limit
This furnace is equipped with an auxiliary manual
reset limit. This limit is designed to function
("trip") in the event of a blower motor failure. If
the limit trips, reset the limit by firmly pressing
the red button in the center of the limit. The limit
is located on the left hand side of the blower
assembly. If the limit will not reset, continues to
trip, or the blower does not function, notify your
NORDYNE Distributor or Service PRO
immediately.
MAINTENANCE
Air Filters
Air filters should be inspected and cleaned
monthly.
Combustion Air and Venting System
Inspect the combustion air and venting system
at the beginning and end of the heating system
for deterioration, blockage, or damage. Clean
the system, if necessary.
LIGHTING AND OPERATING
INSTRUCTIONS FOR CMF PG DIRECT
IGNITION GAS BURNERS
For Your Safety Read Before Lighting or
Operating.
!
WARNING:
If you do not follow these instructions
exactly, a fire or explosion may result
causing property damage, personal in-
jury or loss of life.
A. This appliance does not have a pilot. It is
equipped with an ignition device which
automatically lights the burner. Do not try
to light the burner by hand.
B. BEFORE LIGHTING OR OPERATING
smell all around the appliance area for gas.
Be sure to smell next to the floor because
some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch, do not
use the phone.
• Leave the building immediately, then
call your gas supplier.
• If you cannot reach the gas supplier, call
the fire department.
C. Use only your hand to push in and move
the gas control lever. Never use tools. If
the lever will not push in by hand, don't try
to repair it, call a qualified service techni-
cian. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
E. Should overheating occur, or the gas sup-
ply fail to shut off, turn off the manual gas
valve to the appliance.
Operating Instructions for PG Direct
Ignition Burner
1. STOP! Read the safety information above.
2. Set the thermostat to OFF or to its lowest
setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition
device which automatically lights the
burner. DO NOT try to light the burner by
hand.
5. Turn the latch and open the furnace door.
6. Push in the gas control lever and move to
OFF. DO NOT FORCE.
7. Wait ten (10) minutes to clear out any gas.
If you then smell gas, STOP! Follow
Section B in the safety information above.
If you don’t smell gas, go to the next step.