![Nordyne Air Conditioner / Heat Pump Air Handler Owner'S Manual & Installation Instructions Download Page 19](http://html1.mh-extra.com/html/nordyne/air-conditioner-heat-pump-air-handler/air-conditioner-heat-pump-air-handler_owners-manual-and-installation-instructions_1704619019.webp)
19
Furnace Models E3EB-
010H
012H
015H
017H
020H
023H
023H 5-Ton
Rated Heating Output, Btuh (see note 1)
35,000
41,000
53,000
57,000
70,000
75,000
75,000
Watts (Total kw, Heating Elements & Blower)
10.4
12.0
15.4
16.6
20.4
22.0
22.0
Supply Voltage
240 Volts/60Hz/1-Phase
Heating Elements, No. (Total kw)
2 (10.0)
2 (11.6)
3 (15.0)
3 (16.2)
4 (20.0)
4 (21.6)
4 (21.6)
Blower Wheel Size
10.5” Dia,
8” W
10.5” Dia,
8” W
10.5” Dia,
8” W
10.5” Dia,
8” W
10.5” Dia,
8” W
10.5” Dia,
8” W
11" Dia.,
8" W
Motor Speed, H.P. Rating, Amps
4 Speed, 1/3 HP, 2.9
4 Spd,
3/4HP, 3.8
Amps
Test ESP, in. w.c. Max
0.3
Optional Cooling Available with factory
installed blower
2.0 - 4.0 Ton (See Note 3)
2.0 - 5.0 Ton
Optional Heat Pump Available with factory
installed blower
2.0 - 4.0 Ton
Air Filter (Standard)
16" x 20" x 1" (nominal)
Furnace Dimensions
Width-20" (508mm), Height-29" (737mm) (see note 2), Depth-24 1/2" (623mm)
Table 6. Unit Specifi cations
1. Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x 0.92 (230V),
x 0.84 (220V), x 0.75 (208V).
2. Height is 56” with return air grille installed, 58” with coil cabinet and 72” with coil cabinet and upfl ow stand.
3. The factory installed blower for the EB models can be replaced with a multi-speed blower allowing the units to accept up to 5 tons of air
conditioning.
ELECTRICAL INFORMATION