When you forget the Admin Password, or when the users set the parameters randomly,
you can return to the normal situation by restoring the factory settings, as follows:
Power off, and then power on again, press # key in one second within the indicating light
turn orange, then you will hear two “beep”, and a long beep, admin password has restored
to 888888, while the machine parameters revert to factory settings, the specific default
values are shown in the schedule, other cards and fingerprint information will not be
deleted.
4.5 Operation characteristics in different machine modes
4.5.1 Operation characteristics in Reader mode
In the reader mode, you can add or delete set-card (or fingerprint), adding card (or
fingerprint), or deleting card (or fingerprint), you can add or delete fingerprint users.
It outputs wiegand signal or RS232-TTL signal when reading user card or fingerprint
user.
The functions of the two control wires, LED and BZ are as follows:
LED: Green LED control wire, LED turns to green when low level.
BZ: Buzzer control wire, Buzzer keep sounds when low level.
4.5.2 Operation characteristics in Single-door mode
The default mode is Single-door mode, most applications work in this mode, in this
mode, you could control the electric lock to open the door directly.
4.5.3 Operation characteristics in Interlock mode
Interlock mode is refers to interlocking between two door, installing a machine and a
Magnetic Door Contact for each door , and they have been set in interlock mode. One door
can be opened only when the two doors are closed. If one door has opened, and not yet
closed, then other door can not be opened. Besides, other operations of the interlock mode
are the same as the Single-door mode.
4.5.4 Operation characteristics in Demo mode
Demo mode is the mode for Single-door mode, primarily for display purposes or
without safety needed situation, as a tool to use any card (or fingerprint) to open the door.
In this mode, any card (or fingerprint) can open the door without authorization.
Fingerprint Standalone
Access Control User Manual