ELECTRONIC PUMP CONTROLLER

PRESFLO

®

 is a device that 

starts and stops the pump to 
which it is fitted, thus replacing 
traditional pressure switch / 
surge tank systems.
The pump is started when, as 
a tap is turned on, the pressure 
within the system drops below 
the “start-up pressure” (Pm), 
and is stopped when the flow 

USER’S MANUAL

rate required is zero or less 
than the “shut-off flow rate” 
(Qa). 
PRESFLO

®

’s electronics protect 

the pump against unsuitable 
operating conditions such as 
dry running or repeated start-
ups due to leaks.

Technical specifications

Operating conditions

A. Compatible/non compa-
tible fluids 

PRESFLO

®

 is suitable for use 

with clean water and chemical-
ly non-aggressive liquids. If the 
fluid contains impurities, a filter 
should be fitted upstream.

B. Environmental conditions

PRESFLO

®

 should not be used 

where there is the risk of an 
explosion. The temperature 
of the location should range 
between 0°C and 40°C, and 
the humidity should not exceed 
90%.

C. Power supply

Make sure that the variation 

in the power supply is never 
more or less than 10 % of the 
RATING value. 
Higher values may cause 

damage to the electronic 
components.
PRESFLO

®

 can only be used 

with single-phase pumps.

Working area

Flow rate

Pressure

Shut-off flow rate

Start-up pressure

2

  l/min (0,5 gpm)

Red =

Blue =

Yellow = 

Qa

Pm

Safety regulations 

Before installing or using 
PRESFLO

®

, read this manual 

carefully and thoroughly.
The pump should be installed 
and serviced by qualified per-
sonnel, responsible for making 
the hydraulic and electrical 
connections in compliance with 
the relevant regulations.
DGFLOW

®

 shall not be held lia-

ble for any damage relating to, 
or resulting from, an improper 
use of the product, or for any 
damage relating to, or resulting 
from, servicing or repairs carri-
ed out by unqualified personnel 
and/or with non-OEM spare 
parts. 
The warranty, which is valid 
for 24 months from the date 
of purchase, will no longer be 
applicable should the product 
suffer damage as a conse-
quence of the use of non-OEM 
spare parts, tampering or 
improper use. 
When starting the installation, 
check the following:

- the power supply is switched 
off.
- the power lines can withstand 
the maximum current.
- the cable bushings and circuit 
board cover have been properly 
assembled and secured ( see 
Electrical Connections ).
- Power supply network must 
be fitted with proper protection 
device (fuse or magneto-
thermal relay) upstream of 
PRESFLO

®

When servicing the product, 
check the following:
- the system is not pressurised 
(turn a tap on)
- the power supply is switched 
off.

Emergency Stop

When in use, the pump can 
be stopped in the event of an 
emergency: 
press STOP/RESTART.  

PRESFLO

®

 is put STAND-BY.

Never disassemble

water accumulator

Water accumulator

Losses

- Voltage: ~230 Volt / ~115 Volt 
- Frequency: 50-60 Hz
- Current: 10A, max 12A for 3 sec.
- Current: 12A, max 16A for 3 sec.
- Protection grade: IP 65
- Start-up pressure (Pm): 0,8/1,5/2,2 bar 
   (12/22/32 psi)
- Shut-off flow rate (Qa): 2 litres/min (0,5 gpm)
- Connections: 1” BSP / 1” NPT 
- Maximum working pressure: 10 bar (145 psi)
- Bursting pressure: 40 bar (580 psi) 
- Weight: 650 g
- Protection against: 
  - dry running (automatic restart) 
  - repeated start-ups
- Max room temperature: 40°C
- Max liquid temperature: 55°C
- Type of drive: 1C
- Max manual operations on 
  push button: 1000
- Max automatic operations 
  on relay: 100000
- Class 3A PTI
- Pollution degree : 2
- Max rated voltage pulse: 2,5 kV
- 230V 12A for EMC test
- Pressure operating  
  differential: 10 bar

Before installing

the product, check that 
the RATINGS correspond 
with those required.

2,2

 bar (32 psi)

1,5

 bar (22 psi)

0,8

 bar (12 psi)

Summary of Contents for PRESFLO

Page 1: ... relevant regulations DGFLOW shall not be held lia ble for any damage relating to or resulting from an improper use of the product or for any damage relating to or resulting from servicing or repairs carri ed out by unqualified personnel and or with non OEM spare parts The warranty which is valid for 24 months from the date of purchase will no longer be applicable should the product suffer damage ...

Page 2: ...mp and indicates a dry running error message Attention When the pump is star ted for the first time it may have to be run for longer in order to complete the priming procedure Press the STOP RESTART button to restart the pump and complete the priming procedure Motor Line Nut Seal Cable bushing Attention The cable bushings and circuit board cover must be properly assembled and secured in order to g...

Page 3: ...stopped and put in STAND BY To reset see point 3 If the absence of flow lasts for a few seconds the pump is stopped STAND BY NORMAL SERVICE pump during shutdown See NOTE 1 PRESFLO has detected that the pump is dry running and has therefore stopped it TEMPORARILY Press briefly the pump is started and manually and resumes NORMAL SERVICE See points 2a 2b Hold down the pump is put STAND BY For instruc...

Page 4: ...start up pressure Pm for the chosen application Relocate PRESFLO to another position Install a model with a higher start up pressure Pm Faulty electrical connections or pump out of service Check the electrical connections and that the pump is working PRESFLO STAND BY Reset PRESFLO See Operation point 3 PRESFLO in temporary shut down due to DRY RUNNING due to lack of water Wait for the automatic re...

Reviews: