MicroCoat MC800 Series System
15
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
6.
Low Pressure Switch
Registers low fluid pressure. Connects with low level
switch for press protection.
Must be wired to the press Emergency Stop Circuit
to prevent the press from operating without lubricant
pressure (refer to page 22).
WARNING
7.
Tank Air
Air from this port pressurizes the lubricant reservoir.
8.
Nozzle Air
Air from this port is used to spray the lubricant.
9.
Valve Control Air
Air from this port controls the opening and closing of
the spray valves.
10.
Fluid Outlet
Pressurized lubricant flows from these ports to the
spray valves.
11.
Constant Air Input
The main air supply to the system should be a
minimum of 4.14 bar (60 psi).
12.
Fluid Inlet
Lubricant from the tank reservoir enters the manifold
through this port.
13.
Control Air Input from Solenoid
Activates the system when the press begins
stamping. Minimum 4.14 bar (60 psi) required.
Controller Features (continued)
7
11
8
9
13
12
6
10