© 2021 Nordson Corporation
4-10
Typical Operating Settings
The settings listed here are approximate. You may need to adjust these settings to obtain
the desired results.
Operating Air Pressures
Refer to Table 4-1 for a list of typical operating air pressures. These settings are average
starting points. You may need to adjust these settings depending on your application.
Table 4-1 Typical Operating Air Pressures
Air Pressure
Setting
Input (Minimum)
6 bar (90 psi)
COLLECTOR PULSE
2.75 bar (40 psi)
COLLECTOR FLUIDIZE
0.5 bar (8 psi)
HOPPER FLUIDIZE
0.3 bar (5 psi)
COLLECTOR TRANSFER
2.75 bar (40 psi)
LANCE FLUIDIZE
0.3 bar (5 psi)
Cartridge Filter Pulse Valve Timing Settings
Refer to Table 4-2 for typical pulse valve timing settings. These settings are average
starting points. You may need to adjust the settings if the feed center’s cartridge filters are
not being pulsed sufficiently.
Table 4-2 Table 3-3 Typical Pulse Valve Timer Board Settings
Timer
Setting
Filter Pulse On Duration
0.07 seconds
Filter Pulse Off Duration
10 minutes
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......